Bone mineral density around cementless short stems after reverse shoulder arthroplasty : changes over time and its relationship to stem positioning

© 2023 The Authors.

Détails bibliographiques
Publié dans:JSES international. - 2020. - 8(2024), 1 vom: 15. Jan., Seite 119-125
Auteur principal: Nakazawa, Katsumasa (Auteur)
Autres auteurs: Manaka, Tomoya, Hirakawa, Yoshihiro, Ito, Yoichi, Iio, Ryosuke, Oi, Naoki, Nakamura, Hiroaki
Format: Article en ligne
Langue:English
Publié: 2024
Accès à la collection:JSES international
Sujets:Journal Article Bone mineral density Cementless short stem Dual-energy X-ray absorptiometry Filling ratio Reverse shoulder arthroplasty Stem alignment
LEADER 01000caa a22002652c 4500
001 NLM368014819
003 DE-627
005 20250305183731.0
007 cr uuu---uuuuu
008 240205s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jseint.2023.08.015  |2 doi 
028 5 2 |a pubmed25n1226.xml 
035 |a (DE-627)NLM368014819 
035 |a (NLM)38312281 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Nakazawa, Katsumasa  |e verfasserin  |4 aut 
245 1 0 |a Bone mineral density around cementless short stems after reverse shoulder arthroplasty  |b changes over time and its relationship to stem positioning 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 06.02.2024 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © 2023 The Authors. 
520 |a Background: There are numerous reports of bone adaptation observed on plain radiography studies after the use of cementless short stems in reverse shoulder arthroplasty. However, reports on changes in bone mineral density (BMD) around the stem using dual-energy X-ray absorptiometry (DEXA) are prominently absent. In the present study, we measured BMD around the stem using DEXA and investigated changes over time from postoperative year 1 to year 2. Additionally, the relationship between BMD changes, filling ratio, and stem alignment was examined 
520 |a Methods: Forty-seven patients with short cementless stems who could be assessed via DEXA at 1-2 years postoperatively were included. After dividing the zones around the stem into 5, the BMD in each zone was measured, in addition to BMD changes and amount of change from postoperative year 1 to year 2. The relationship between filling ratio and stem alignment on postoperative plain radiography was assessed 
520 |a Results: A significant decrease in BMD in zone 3 was observed between postoperative year 1 and year 2 (P = .02). Regarding filling ratio and stem alignment, a negative correlation between valgus stem alignment and BMD change observed in zone 1 (r = -0.470, P < .01). In addition, stem valgus greater than 6° correlated with a significant decrease in BMD in zone 1. (P = .01). No significant differences were found in the other zones. Furthermore, there was no correlation between filling ratio and BMD change 
520 |a Conclusion: In reverse shoulder arthroplasty cementless short stems, changes that that occurred between postoperative year 1 to year 2 demonstrated a decrease in BMD in zone 3. In addition, a decrease in BMD in zone 1 was observed with a stem alignment of valgus 6° or higher, suggesting that stem alignment within valgus 6° is required to prevent a decrease in BMD 
650 4 |a Journal Article 
650 4 |a Bone mineral density 
650 4 |a Cementless short stem 
650 4 |a Dual-energy X-ray absorptiometry 
650 4 |a Filling ratio 
650 4 |a Reverse shoulder arthroplasty 
650 4 |a Stem alignment 
700 1 |a Manaka, Tomoya  |e verfasserin  |4 aut 
700 1 |a Hirakawa, Yoshihiro  |e verfasserin  |4 aut 
700 1 |a Ito, Yoichi  |e verfasserin  |4 aut 
700 1 |a Iio, Ryosuke  |e verfasserin  |4 aut 
700 1 |a Oi, Naoki  |e verfasserin  |4 aut 
700 1 |a Nakamura, Hiroaki  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t JSES international  |d 2020  |g 8(2024), 1 vom: 15. Jan., Seite 119-125  |w (DE-627)NLM307818438  |x 2666-6383  |7 nnas 
773 1 8 |g volume:8  |g year:2024  |g number:1  |g day:15  |g month:01  |g pages:119-125 
856 4 0 |u http://dx.doi.org/10.1016/j.jseint.2023.08.015  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_50 
912 |a GBV_ILN_65 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 8  |j 2024  |e 1  |b 15  |c 01  |h 119-125