Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal Tract

© 2024 The Authors. Advanced Materials published by Wiley‐VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - 36(2024), 19 vom: 09. Mai, Seite e2312735
1. Verfasser: Oldroyd, Poppy (VerfasserIn)
Weitere Verfasser: Oldroyd, Sophie, Meng, Michelle, Makwana, Rajesh, Sanger, Gareth, Bulmer, David, Malliaras, George G, Owens, Róisín M
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article PDMS PEDOT:PSS bioelectronics electrodes electrophysiology organic stretchable Polystyrenes Dimethylpolysiloxanes mehr... baysilon 63148-62-9 poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) Polymers Bridged Bicyclo Compounds, Heterocyclic Thiophenes poly(3,4-ethylene dioxythiophene)
Beschreibung
Zusammenfassung:© 2024 The Authors. Advanced Materials published by Wiley‐VCH GmbH.
Devices interfacing with biological tissues can provide valuable insights into function, disease, and metabolism through electrical and mechanical signals. However, certain neuromuscular tissues, like those in the gastrointestinal tract, undergo significant strains of up to 40%. Conventional inextensible devices cannot capture the dynamic responses in these tissues. This study introduces electrodes made from poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and polydimethylsiloxane (PDMS) that enable simultaneous monitoring of electrical and mechanical responses of gut tissue. The soft PDMS layers conform to tissue surfaces during gastrointestinal movement. Dopants, including Capstone FS-30 and polyethylene glycol, are explored to enhance the conductivity, electrical sensitivity to strain, and stability of the PEDOT:PSS. The devices are fabricated using shadow masks and solution-processing techniques, providing a faster and simpler process than traditional clean-room-based lithography. Tested on ex vivo mouse colon and human stomach, the device recorded voltage changes of up to 300 µV during contraction and distension consistent with muscle activity, while simultaneously recording resistance changes of up to 150% due to mechanical strain. These devices detect and respond to chemical stimulants and blockers, and can induce contractions through electrical stimulation. They hold great potential for studying and treating complex disorders like irritable bowel syndrome and gastroparesis