Two-Dimensional Nickel Porphyrinic Metal-Organic Framework-Modified Electrode for Electrochemical Sensing

Due to their highly exposed active sites and high aspect ratio caused by their substantial lateral dimension and thin thickness, two-dimensional (2D) metal-organic framework (MOF) nanosheets are currently considered a potential hybrid material for electrochemical sensing. Herein, we present a nickel...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 40(2024), 5 vom: 06. Feb., Seite 2708-2718
1. Verfasser: Boakye, Andrews (VerfasserIn)
Weitere Verfasser: Yu, Kun, Chai, Huining, Xu, Tailin, Houston, Lystra Sarah, Asinyo, Benjamin K, Zhang, Xueji, Zhang, Guangyao, Qu, Lijun
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
Beschreibung
Zusammenfassung:Due to their highly exposed active sites and high aspect ratio caused by their substantial lateral dimension and thin thickness, two-dimensional (2D) metal-organic framework (MOF) nanosheets are currently considered a potential hybrid material for electrochemical sensing. Herein, we present a nickel-based porphyrinic MOF nanosheet as a versatile and robust platform with an enhanced electrochemical detection performance. It is important to note that the nickel porphyrin ligand reacted with Cu(NO3)2·3H2O in a solvothermal process, with polyvinylpyrrolidone (PVP) acting as the surfactant to control the anisotropic development of creating a 2D Cu-TCPP(Ni) MOF nanosheet structure. To realize the exceptional selectivity, sensitivity, and stability of the synthesized 2D Cu-TCPP(Ni) MOF nanosheet, a laser-induced graphene electrode was modified with the MOF nanosheet and employed as a sensor for the detection of p-nitrophenol (p-NP). With a detection range of 0.5-200 μM for differential pulse voltammetry (DPV) and 0.9-300 μM for cyclic voltammetry (CV), the proposed sensor demonstrated enhanced electrochemical performance, with the limit of detection (LOD) for DPV and CV as 0.1 and 0.3 μM, respectively. The outstanding outcome of the sensor is attributed to the 2D Cu-TCPP(Ni) MOF nanosheet's substantial active surface area, innate catalytic activity, and superior adsorption capacity. Furthermore, it is anticipated that the proposed electrode sensor will make it possible to create high-performance electrochemical sensors for environmental point-of-care testing since it successfully detected p-NP in real sample analysis
Beschreibung:Date Revised 06.02.2024
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:1520-5827
DOI:10.1021/acs.langmuir.3c03257