|
|
|
|
LEADER |
01000caa a22002652c 4500 |
001 |
NLM365791822 |
003 |
DE-627 |
005 |
20250305134133.0 |
007 |
cr uuu---uuuuu |
008 |
231226s2024 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1002/adma.202309452
|2 doi
|
028 |
5 |
2 |
|a pubmed25n1218.xml
|
035 |
|
|
|a (DE-627)NLM365791822
|
035 |
|
|
|a (NLM)38088453
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Li, Dan
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Ultrasensitive NIR-II Ratiometric Nanothermometers for 3D In Vivo Thermal Imaging
|
264 |
|
1 |
|c 2024
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 15.03.2024
|
500 |
|
|
|a Date Revised 15.03.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a © 2023 Wiley-VCH GmbH.
|
520 |
|
|
|a Luminescent nanothermometry, particularly the one based on ratiometric, has sparked intense research for non-invasive in vivo or intracellular temperature mapping, empowering their uses as diagnosis tools in biomedicine. However, ratiometric detection still suffers from biased sensing induced by wavelength-dependent tissue absorption and scattering, low thermal sensitivity (Sr ), and lack of imaging depth information. Herein, this work constructs an ultrasensitive NIR-II ratiometric nanothermometer with self-calibrating ability for 3D in vivo thermographic imaging, in which temperature-insensitive lanthanide nanocrystals and strongly temperature-quenched Ag2 S quantum dots are co-assembled to form a hybrid nanocomposite material. Precise control over the amount ratio between two sub-materials enables the manipulation of heat-activated back energy transfer from Ag2 S to Yb3+ in lanthanide nanoparticles, thereby rendering Sr up to 7.8% °C-1 at 43.5 °C, and higher than 6.5% °C-1 over the entire physiological temperature range. Moreover, the luminescence intensity ratio between two separated spectral regions within the narrow Yb3+ emission peak is used to determine the depth information of nanothermometers in living mice and correct the effect of tissue depth on 2D thermographic imaging, and therefore allows a proof-of-concept demonstration of accurate 3D in vivo thermographic imaging, constituting a solid step toward the development of advanced ratiometric nanothermometry for biological applications
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a 3D thermographic imaging
|
650 |
|
4 |
|a NIR-II
|
650 |
|
4 |
|a ratiometric luminescent nanothermometry
|
650 |
|
4 |
|a self-calibrating program
|
650 |
|
4 |
|a thermal sensitivity
|
650 |
|
7 |
|a Lanthanoid Series Elements
|2 NLM
|
700 |
1 |
|
|a Jia, Mochen
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Jia, Tao
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Chen, Guanying
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Advanced materials (Deerfield Beach, Fla.)
|d 1998
|g 36(2024), 11 vom: 01. März, Seite e2309452
|w (DE-627)NLM098206397
|x 1521-4095
|7 nnas
|
773 |
1 |
8 |
|g volume:36
|g year:2024
|g number:11
|g day:01
|g month:03
|g pages:e2309452
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1002/adma.202309452
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 36
|j 2024
|e 11
|b 01
|c 03
|h e2309452
|