Investigation of baffle configurations on the water disinfection efficiency using ultraviolet C light-emitting diodes

In this study, the effect of baffle configuration on the water disinfection efficiency of a planar photoreactor equipped with ultraviolet C light-emitting diodes (UV-C LEDs) was investigated. The results indicated that the configuration of the baffles influenced the hydrodynamics inside the flow cha...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1993. - 45(2024), 25 vom: 15. Okt., Seite 5359-5367
1. Verfasser: Wang, Chien-Ping (VerfasserIn)
Weitere Verfasser: Li, Ming-Han, Lo, Chen-Lun
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Journal Article UV fluence UV-C LED baffle configuration hydrodynamics water disinfection
LEADER 01000caa a22002652 4500
001 NLM365384127
003 DE-627
005 20241023232549.0
007 cr uuu---uuuuu
008 231226s2024 xx |||||o 00| ||eng c
024 7 |a 10.1080/09593330.2023.2291420  |2 doi 
028 5 2 |a pubmed24n1577.xml 
035 |a (DE-627)NLM365384127 
035 |a (NLM)38047446 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Wang, Chien-Ping  |e verfasserin  |4 aut 
245 1 0 |a Investigation of baffle configurations on the water disinfection efficiency using ultraviolet C light-emitting diodes 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 23.10.2024 
500 |a Date Revised 23.10.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a In this study, the effect of baffle configuration on the water disinfection efficiency of a planar photoreactor equipped with ultraviolet C light-emitting diodes (UV-C LEDs) was investigated. The results indicated that the configuration of the baffles influenced the hydrodynamics inside the flow channel and thus affected the microbial trajectory, and exposure time. Accordingly, a modified serpentine configuration was developed to enhance the UV light exposure of microbes in water and improve the reactor performance for microbial inactivation. According to the simulation results, the quarter-circle baffles used in the modified serpentine configuration increased the microbial path length along the flow channel. However, because the cross-sectional area of the flow channel decreased, this configuration increased the water velocity. A modified serpentine configuration with a baffle radius of 5 mm achieved the longest microbial exposure time and highest inactivation value for Escherichia coli. At a water flow rate of 160 mL/min, this configuration achieved a UV fluence of 15.2 mJ/cm2 and an inactivation value of 3.8 log, which were approximately 22% and 0.4 log higher than those obtained with the traditional serpentine configuration, respectively. In addition, the maximum water flow rate at which the UV reactor achieved an inactivation value of 4.0 log was 154 mL/min at a baffle radius of 5 mm. This flow rate was 11.5% higher than that obtained with the traditional serpentine configuration. These close agreements between the experimental and simulation results confirmed the strong capability of the proposed modified serpentine configuration to improve reactor performance 
650 4 |a Journal Article 
650 4 |a UV fluence 
650 4 |a UV-C LED 
650 4 |a baffle configuration 
650 4 |a hydrodynamics 
650 4 |a water disinfection 
700 1 |a Li, Ming-Han  |e verfasserin  |4 aut 
700 1 |a Lo, Chen-Lun  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Environmental technology  |d 1993  |g 45(2024), 25 vom: 15. Okt., Seite 5359-5367  |w (DE-627)NLM098202545  |x 1479-487X  |7 nnns 
773 1 8 |g volume:45  |g year:2024  |g number:25  |g day:15  |g month:10  |g pages:5359-5367 
856 4 0 |u http://dx.doi.org/10.1080/09593330.2023.2291420  |3 Volltext 