Three-Dimensional Touch Device with Two Terminals

© 2023 Wiley-VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - 35(2023), 42 vom: 01. Okt., Seite e2305697
1. Verfasser: Cho, Youngjun (VerfasserIn)
Weitere Verfasser: Kim, Taehoon, Kim, Gwangmook, Do, Hyung Wan, Kim, Seung-Rok, Park, Jin-Woo, Myoung, Jae-Min, Shim, Wooyoung
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article 3D touch capacitive pressure sensors gradient patterns inkjet printing two terminals
LEADER 01000naa a22002652 4500
001 NLM361148003
003 DE-627
005 20231226084528.0
007 cr uuu---uuuuu
008 231226s2023 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.202305697  |2 doi 
028 5 2 |a pubmed24n1203.xml 
035 |a (DE-627)NLM361148003 
035 |a (NLM)37616471 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cho, Youngjun  |e verfasserin  |4 aut 
245 1 0 |a Three-Dimensional Touch Device with Two Terminals 
264 1 |c 2023 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.10.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © 2023 Wiley-VCH GmbH. 
520 |a A crossbar array is an essential element that determines the operating position and simplifies the structure of devices. However, in the crossbar array, wiring numerous electrodes to address many positions poses significant challenges. In this study, a method is proposed that utilizes only two electrodes to determine multiple positions. The method significantly simplifies the wiring and device fabrication process. Instead of defining the node location of the crossbar, it is experimentally demonstrated that the x-y-z coordinates can be determined from i) the resistance change as a function of distance, ii) the resistance variation influenced by the electrode composition, and iii) capacitance fluctuation resulting from changes in the dielectric thickness. By employing two-terminal transparent electrodes, a fully functional 3D touch device is successfully fabricated, introducing a groundbreaking approach to simplify input device architectures 
650 4 |a Journal Article 
650 4 |a 3D touch 
650 4 |a capacitive pressure sensors 
650 4 |a gradient patterns 
650 4 |a inkjet printing 
650 4 |a two terminals 
700 1 |a Kim, Taehoon  |e verfasserin  |4 aut 
700 1 |a Kim, Gwangmook  |e verfasserin  |4 aut 
700 1 |a Do, Hyung Wan  |e verfasserin  |4 aut 
700 1 |a Kim, Seung-Rok  |e verfasserin  |4 aut 
700 1 |a Park, Jin-Woo  |e verfasserin  |4 aut 
700 1 |a Myoung, Jae-Min  |e verfasserin  |4 aut 
700 1 |a Shim, Wooyoung  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials (Deerfield Beach, Fla.)  |d 1998  |g 35(2023), 42 vom: 01. Okt., Seite e2305697  |w (DE-627)NLM098206397  |x 1521-4095  |7 nnns 
773 1 8 |g volume:35  |g year:2023  |g number:42  |g day:01  |g month:10  |g pages:e2305697 
856 4 0 |u http://dx.doi.org/10.1002/adma.202305697  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 35  |j 2023  |e 42  |b 01  |c 10  |h e2305697