BL09XU : an advanced hard X-ray photoelectron spectroscopy beamline of SPring-8

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 30(2023), Pt 5 vom: 01. Sept., Seite 1013-1022
1. Verfasser: Yasui, Akira (VerfasserIn)
Weitere Verfasser: Takagi, Yasumasa, Osaka, Taito, Senba, Yasunori, Yamazaki, Hiroshi, Koyama, Takahisa, Yumoto, Hirokatsu, Ohashi, Haruhiko, Motomura, Koji, Nakajima, Kyo, Sugahara, Michihiro, Kawamura, Naomi, Tamasaku, Kenji, Tamenori, Yusuke, Yabashi, Makina
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article HAXPES X-ray optics beamlines double-crystal X-ray phase retarders hard X-ray photoelectron spectroscopy high-flux microbeams
LEADER 01000naa a22002652 4500
001 NLM361087934
003 DE-627
005 20231226084413.0
007 cr uuu---uuuuu
008 231226s2023 xx |||||o 00| ||eng c
024 7 |a 10.1107/S160057752300629X  |2 doi 
028 5 2 |a pubmed24n1203.xml 
035 |a (DE-627)NLM361087934 
035 |a (NLM)37610343 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yasui, Akira  |e verfasserin  |4 aut 
245 1 0 |a BL09XU  |b an advanced hard X-ray photoelectron spectroscopy beamline of SPring-8 
264 1 |c 2023 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 08.09.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a The BL09XU beamline of SPring-8 has been reorganized into a beamline dedicated for hard X-ray photoelectron spectroscopy (HAXPES) to provide advanced capabilities with upgraded optical instruments. The beamline has two HAXPES analyzers to cover a wide range of applications. Two sets of double channel-cut crystal monochromators with the Si(220) and (311) reflections were installed to perform resonant HAXPES analyses with a total energy resolution of less than 300 meV over a wide energy range (4.9-12 keV) while achieving a fixed-exit condition. A double-crystal X-ray phase retarder using diamond crystals controls the polarization state with a high degree of polarization over 0.9 in the wide energy range 5.9-9.5 keV. Each HAXPES analyzer is equipped with a focusing mirror to provide a high-flux microbeam. The design and performance of the upgraded instruments are presented 
650 4 |a Journal Article 
650 4 |a HAXPES 
650 4 |a X-ray optics 
650 4 |a beamlines 
650 4 |a double-crystal X-ray phase retarders 
650 4 |a hard X-ray photoelectron spectroscopy 
650 4 |a high-flux microbeams 
700 1 |a Takagi, Yasumasa  |e verfasserin  |4 aut 
700 1 |a Osaka, Taito  |e verfasserin  |4 aut 
700 1 |a Senba, Yasunori  |e verfasserin  |4 aut 
700 1 |a Yamazaki, Hiroshi  |e verfasserin  |4 aut 
700 1 |a Koyama, Takahisa  |e verfasserin  |4 aut 
700 1 |a Yumoto, Hirokatsu  |e verfasserin  |4 aut 
700 1 |a Ohashi, Haruhiko  |e verfasserin  |4 aut 
700 1 |a Motomura, Koji  |e verfasserin  |4 aut 
700 1 |a Nakajima, Kyo  |e verfasserin  |4 aut 
700 1 |a Sugahara, Michihiro  |e verfasserin  |4 aut 
700 1 |a Kawamura, Naomi  |e verfasserin  |4 aut 
700 1 |a Tamasaku, Kenji  |e verfasserin  |4 aut 
700 1 |a Tamenori, Yusuke  |e verfasserin  |4 aut 
700 1 |a Yabashi, Makina  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 30(2023), Pt 5 vom: 01. Sept., Seite 1013-1022  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:30  |g year:2023  |g number:Pt 5  |g day:01  |g month:09  |g pages:1013-1022 
856 4 0 |u http://dx.doi.org/10.1107/S160057752300629X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 30  |j 2023  |e Pt 5  |b 01  |c 09  |h 1013-1022