Regulating Exciton De-Trapping of Te4+ -Doped Zero-Dimensional Scandium-Halide Perovskite for Fluorescence Thermometry with Record High Time-Resolved Thermal Sensitivity

© 2023 Wiley-VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - 35(2023), 44 vom: 30. Nov., Seite e2305495
1. Verfasser: Li, Gaoqiang (VerfasserIn)
Weitere Verfasser: Chen, Xu, Wang, Meng, Cheng, Shanshan, Yang, Dongwen, Wu, Di, Han, Yanbing, Jia, Mochen, Li, Xinjian, Zhang, Yu, Shan, Chongxin, Shi, Zhifeng
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article fluorescence thermometry ion doping lead-free perovskites self-trapped excitons thermal sensitivity
Beschreibung
Zusammenfassung:© 2023 Wiley-VCH GmbH.
Fluorescence thermometry has been propelled to the forefront of scientific attention due to its high spatial resolution and remote non-invasive detection. However, recent generations of thermometers still suffer from limited thermal sensitivity (Sr ) below 10% change per Kelvin. Herein, this work presents an ideal temperature-responsive fluorescence material through Te4+ -doped 0D Cs2 ScCl5 ·H2 O, in which isolated polyhedrons endow highly localized electronic structures, and the strong electron-phonon coupling facilitates the formation of self-trapped excitons (STEs). With rising temperature, the dramatic asymmetric expansion of the soft lattice induces increased defects, strong exciton-phonon coupling, and low thermal activation energy, which evokes a rapid de-trapping process of STEs, enabling several orders of magnitude changes in the fluorescence lifetime over a narrow temperature range. After regulating the de-trapping process with different Te4+ doping, a record-high Sr (27.36% K-1 ) of fluorescence lifetime-based detection is achieved at 325 K. The robust stability against multiple heating/cooling cycles and long-term measurements enables a low temperature uncertainty of 0.067 K. Further, the developed thermometers are demonstrated for the remote local monitoring of operating temperature on internal electronic components. It is believed that this work constitutes a solid step towards building the next generation of ultrasensitive thermometers based on low-dimensional metal halides
Beschreibung:Date Revised 02.11.2023
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:1521-4095
DOI:10.1002/adma.202305495