Estimation of Aquifer Transmissivity From Analysis of Long-Term Monitoring With the Thiem Solution

© 2023 National Ground Water Association.

Bibliographische Detailangaben
Veröffentlicht in:Ground water. - 1979. - 62(2024), 2 vom: 07. März, Seite 295-302
1. Verfasser: Henry, Joel C (VerfasserIn)
Weitere Verfasser: Neville, Christopher J, Olson, Alyssa N
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Ground water
Schlagworte:Journal Article Water 059QF0KO0R
LEADER 01000caa a22002652 4500
001 NLM357903315
003 DE-627
005 20240804232117.0
007 cr uuu---uuuuu
008 231226s2024 xx |||||o 00| ||eng c
024 7 |a 10.1111/gwat.13332  |2 doi 
028 5 2 |a pubmed24n1491.xml 
035 |a (DE-627)NLM357903315 
035 |a (NLM)37288488 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Henry, Joel C  |e verfasserin  |4 aut 
245 1 0 |a Estimation of Aquifer Transmissivity From Analysis of Long-Term Monitoring With the Thiem Solution 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 06.03.2024 
500 |a Date Revised 03.08.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2023 National Ground Water Association. 
520 |a The application of the Thiem equation to support the interpretation of comprehensive long-term monitoring datasets, made possible through modern datalogging technology, is presented as an alternative to constant-rate aquifer testing to obtain representative transmissivity estimates in settings where controlled hydraulic testing may be impractical. Water levels logged at regular intervals can be readily converted to average water levels over time periods corresponding to periods of known pumping rates. By regressing average water levels during multiple time periods of known but variable withdrawal rates, steady-state conditions can be approximated and Thiem's solution applied to estimate transmissivity, without performance of a constant-rate aquifer test. Although the application is limited to settings where changes in aquifer storage are negligible, by regressing long data sets to parse interferences the method may characterize aquifer conditions over a much wider radius than short-term, non-equilibrium tests. As with all aquifer testing, informed interpretation is critical to identifying and resolving aquifer heterogeneities and interferences 
650 4 |a Journal Article 
650 7 |a Water  |2 NLM 
650 7 |a 059QF0KO0R  |2 NLM 
700 1 |a Neville, Christopher J  |e verfasserin  |4 aut 
700 1 |a Olson, Alyssa N  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ground water  |d 1979  |g 62(2024), 2 vom: 07. März, Seite 295-302  |w (DE-627)NLM098182528  |x 1745-6584  |7 nnns 
773 1 8 |g volume:62  |g year:2024  |g number:2  |g day:07  |g month:03  |g pages:295-302 
856 4 0 |u http://dx.doi.org/10.1111/gwat.13332  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 62  |j 2024  |e 2  |b 07  |c 03  |h 295-302