Dual-Emissive Carbon Dots : Exploring Their Fluorescence Properties for Sensitive Turn-Off-On Recognition of Ferric and Pyrophosphate Ions and Its Application in Fluorometric Detection of the Loop-Mediated Isothermal Amplification Reaction

In this study, dual-emissive carbon dots (CDs) were prepared using p-phenylenediamine (pPDA) and phytic acid (PA) precursors via a one-pot-hydrothermal method. The photophysical, morphological, and structural characterization of CDs was carried out using absorption, fluorescence, Fourier transform i...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1985. - 39(2023), 16 vom: 25. Apr., Seite 5779-5792
1. Verfasser: Selva Sharma, Arumugam (VerfasserIn)
Weitere Verfasser: Suresh Nair, Swathy, Varghese, Amal Wilson, Usha, Anjana, Varghese, Ria Elza, Joseph, Roy, Thekkuveettil, Anoopkumar
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Carbon 7440-44-0 diphosphoric acid 4E862E7GRQ Iron E1UOL152H7 Cations
Beschreibung
Zusammenfassung:In this study, dual-emissive carbon dots (CDs) were prepared using p-phenylenediamine (pPDA) and phytic acid (PA) precursors via a one-pot-hydrothermal method. The photophysical, morphological, and structural characterization of CDs was carried out using absorption, fluorescence, Fourier transform infrared (FT-IR) spectroscopy, nuclear magnetic resonance (NMR), and high-resolution transmission electron microscopy (HR-TEM) analysis. The as-prepared CDs displayed dual-fluorescence peaks at 525 and 620 nm upon excitation at 450 nm. The CDs showed good photostability and exhibited solvent-dependent fluorescence properties. The solvatochromic behavior of CDs was utilized to detect water content in organic solvents. Furthermore, the dual-emissive property of CDs was utilized for the sequential detection of ferric (Fe3+) and pyrophosphate ions (PPi) by a fluorescence turn-off-on mechanism. The proposed assay showed appreciable fluorescence response toward Fe3+ and PPi with high selectivity and good tolerance for common interfering ions. The potential practical application of the CD probe was ascertained by carrying out the fluorometric detection of PPi to affirm the loop-mediated isothermal amplification (LAMP) reaction specific for Mycobacterium tuberculosis (negative and positive clinical samples)
Beschreibung:Date Completed 27.04.2023
Date Revised 10.05.2023
published: Print-Electronic
Citation Status MEDLINE
ISSN:1520-5827
DOI:10.1021/acs.langmuir.3c00041