|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM354726900 |
003 |
DE-627 |
005 |
20231226062834.0 |
007 |
cr uuu---uuuuu |
008 |
231226s2023 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1002/mrc.5349
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1182.xml
|
035 |
|
|
|a (DE-627)NLM354726900
|
035 |
|
|
|a (NLM)36967631
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Fondeur, Fernando
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high-level supernatant waste at the Savannah River Site (SRS)
|
264 |
|
1 |
|c 2023
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 08.06.2023
|
500 |
|
|
|a Date Revised 08.06.2023
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a Published 2023. This article is a U.S. Government work and is in the public domain in the USA.
|
520 |
|
|
|a The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH2 peak with a signal-to-noise ratio of 36
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a 1H
|
650 |
|
4 |
|a NMR
|
650 |
|
4 |
|a glycolate anion
|
650 |
|
4 |
|a solvent suppression
|
650 |
|
4 |
|a standard addition method
|
650 |
|
4 |
|a supernatant
|
700 |
1 |
|
|a White, Thomas L
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Coleman, Charles J
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Diprete, David P
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Nash, Charles A
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Looney, Brian B
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Magnetic resonance in chemistry : MRC
|d 1985
|g 61(2023), 7 vom: 27. Juli, Seite 407-417
|w (DE-627)NLM098179667
|x 1097-458X
|7 nnns
|
773 |
1 |
8 |
|g volume:61
|g year:2023
|g number:7
|g day:27
|g month:07
|g pages:407-417
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1002/mrc.5349
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 61
|j 2023
|e 7
|b 27
|c 07
|h 407-417
|