Total scattering measurements at the Australian Synchrotron Powder Diffraction beamline : capabilities and limitations

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 30(2023), Pt 2 vom: 01. März, Seite 327-339
1. Verfasser: D'Angelo, Anita M (VerfasserIn)
Weitere Verfasser: Brand, Helen E A, Mitchell, Valerie D, Hamilton, Jessica L, Oldfield, Daniel, Liu, Amelia C Y, Gu, Qinfen
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Mythen-II detector pair distribution function powder X-ray diffraction total scattering
LEADER 01000naa a22002652 4500
001 NLM353975710
003 DE-627
005 20231226061224.0
007 cr uuu---uuuuu
008 231226s2023 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577522011614  |2 doi 
028 5 2 |a pubmed24n1179.xml 
035 |a (DE-627)NLM353975710 
035 |a (NLM)36891846 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a D'Angelo, Anita M  |e verfasserin  |4 aut 
245 1 0 |a Total scattering measurements at the Australian Synchrotron Powder Diffraction beamline  |b capabilities and limitations 
264 1 |c 2023 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.03.2023 
500 |a Date Revised 13.03.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a This study describes the capabilities and limitations of carrying out total scattering experiments on the Powder Diffraction (PD) beamline at the Australian Synchrotron, ANSTO. A maximum instrument momentum transfer of 19 Å-1 can be achieved if the data are collected at 21 keV. The results detail how the pair distribution function (PDF) is affected by Qmax, absorption and counting time duration at the PD beamline, and refined structural parameters exemplify how the PDF is affected by these parameters. There are considerations when performing total scattering experiments at the PD beamline, including (1) samples need to be stable during data collection, (2) highly absorbing samples with a μR > 1 always require dilution and (3) only correlation length differences >0.35 Å may be resolved. A case study comparing the PDF atom-atom correlation lengths with EXAFS-derived radial distances of Ni and Pt nanocrystals is also presented, which shows good agreement between the two techniques. The results here can be used as a guide for researchers considering total scattering experiments at the PD beamline or similarly setup beamlines 
650 4 |a Journal Article 
650 4 |a Mythen-II detector 
650 4 |a pair distribution function 
650 4 |a powder X-ray diffraction 
650 4 |a total scattering 
700 1 |a Brand, Helen E A  |e verfasserin  |4 aut 
700 1 |a Mitchell, Valerie D  |e verfasserin  |4 aut 
700 1 |a Hamilton, Jessica L  |e verfasserin  |4 aut 
700 1 |a Oldfield, Daniel  |e verfasserin  |4 aut 
700 1 |a Liu, Amelia C Y  |e verfasserin  |4 aut 
700 1 |a Gu, Qinfen  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 30(2023), Pt 2 vom: 01. März, Seite 327-339  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:30  |g year:2023  |g number:Pt 2  |g day:01  |g month:03  |g pages:327-339 
856 4 0 |u http://dx.doi.org/10.1107/S1600577522011614  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 30  |j 2023  |e Pt 2  |b 01  |c 03  |h 327-339