Multiplexed Ultrasensitive Sample-to-Answer RT-LAMP Chip for the Identification of SARS-CoV-2 and Influenza Viruses

© 2023 The Authors. Advanced Materials published by Wiley-VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - 35(2023), 10 vom: 17. März, Seite e2207138
1. Verfasser: Song, Minsun (VerfasserIn)
Weitere Verfasser: Hong, SoonGweon, Lee, Luke P
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article SARS-CoV-2 multiplexing on-chip sample preparation preconcentration reverse transcription loop-mediated isothermal amplification sample-to-answer ultrasensitive point-of-care chips
LEADER 01000naa a22002652 4500
001 NLM349116989
003 DE-627
005 20231226041846.0
007 cr uuu---uuuuu
008 231226s2023 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.202207138  |2 doi 
028 5 2 |a pubmed24n1163.xml 
035 |a (DE-627)NLM349116989 
035 |a (NLM)36398425 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Song, Minsun  |e verfasserin  |4 aut 
245 1 0 |a Multiplexed Ultrasensitive Sample-to-Answer RT-LAMP Chip for the Identification of SARS-CoV-2 and Influenza Viruses 
264 1 |c 2023 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 14.03.2023 
500 |a Date Revised 14.03.2023 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2023 The Authors. Advanced Materials published by Wiley-VCH GmbH. 
520 |a Prompt on-site diagnosis of SARS-CoV-2 with other respiratory infections will have minimized the global impact of the COVID-19 pandemic through rapid, effective management. However, no such multiplex point-of-care (POC) chip has satisfied a suitable sensitivity of gold-standard nucleic acid amplification tests (NAATs). Here, a rapid multiplexed ultrasensitive sample-to-answer loop-mediated isothermal amplification (MUSAL) chip operated by simple LED-driven photothermal amplification to detect six targets from single-swab sampling is presented. First, the MUSAL chip allows ultrafast on-chip sample preparation with ≈500-fold preconcentration at a rate of 1.2 mL min-1 . Second, the chip enables contamination-free amplification using autonomous target elution into on-chip reagents by photothermal activation. Finally, the chip accomplishes multiplexed on-chip diagnostics of SARS-CoV-2 and influenza viruses with a limit of detection (LoD) of 0.5 copies µL-1 . The rapid, ultrasensitive, cost-effective sample-to-answer chip with a multiplex capability will allow timely management of various pandemics situations that may be faced shortly 
650 4 |a Journal Article 
650 4 |a SARS-CoV-2 
650 4 |a multiplexing 
650 4 |a on-chip sample preparation 
650 4 |a preconcentration 
650 4 |a reverse transcription loop-mediated isothermal amplification 
650 4 |a sample-to-answer 
650 4 |a ultrasensitive point-of-care chips 
700 1 |a Hong, SoonGweon  |e verfasserin  |4 aut 
700 1 |a Lee, Luke P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials (Deerfield Beach, Fla.)  |d 1998  |g 35(2023), 10 vom: 17. März, Seite e2207138  |w (DE-627)NLM098206397  |x 1521-4095  |7 nnns 
773 1 8 |g volume:35  |g year:2023  |g number:10  |g day:17  |g month:03  |g pages:e2207138 
856 4 0 |u http://dx.doi.org/10.1002/adma.202207138  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 35  |j 2023  |e 10  |b 17  |c 03  |h e2207138