Reusable Fundus Model for Laser Retinopexy Simulation and Training

BACKGROUND AND OBJECTIVE: To describe a simulation technique for laser barrier retinopexy as an option for ophthalmologists in training to practice slit lamp and laser indirect ophthalmoscopy (LIO) retinopexy

Bibliographische Detailangaben
Veröffentlicht in:Ophthalmic surgery, lasers & imaging retina. - 2013. - 53(2022), 11 vom: 15. Nov., Seite 606-609
1. Verfasser: Hudson, Julia L (VerfasserIn)
Weitere Verfasser: Salazar, Humberto, Kunkler, Anne L, Fan, Kenneth C, Sridhar, Jayanth S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Ophthalmic surgery, lasers & imaging retina
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM348920431
003 DE-627
005 20231226041424.0
007 cr uuu---uuuuu
008 231226s2022 xx |||||o 00| ||eng c
024 7 |a 10.3928/23258160-20221019-01  |2 doi 
028 5 2 |a pubmed24n1163.xml 
035 |a (DE-627)NLM348920431 
035 |a (NLM)36378610 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Hudson, Julia L  |e verfasserin  |4 aut 
245 1 0 |a Reusable Fundus Model for Laser Retinopexy Simulation and Training 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.11.2022 
500 |a Date Revised 26.12.2022 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a BACKGROUND AND OBJECTIVE: To describe a simulation technique for laser barrier retinopexy as an option for ophthalmologists in training to practice slit lamp and laser indirect ophthalmoscopy (LIO) retinopexy 
520 |a MATERIALS AND METHODS: A commercially available fundus model and laser printer labels were used to simulate laser retinopexy of horseshoe tears (HST). At two time points, seven first-year residents and seven second-year residents were asked to complete three rows of laser burns around HSTs and the times were recorded 
520 |a RESULTS: Second-year residents completed simulated retinopexies in less time than first-year residents on both the slit lamp (P = .001) and with LIO (P = .001). Second-year residents were also statistically more efficient when retested at the second time point (P = .003 and P = .005, slit lamp and LIO, respectively) 
520 |a CONCLUSION: This novel educational model is able to capture differences in training level and increased experience among ophthalmology trainees, and may be beneficial as part of a structured teaching program. [Ophthalmic Surg Lasers Imaging Retina 2022;53:606-609.] 
650 4 |a Journal Article 
700 1 |a Salazar, Humberto  |e verfasserin  |4 aut 
700 1 |a Kunkler, Anne L  |e verfasserin  |4 aut 
700 1 |a Fan, Kenneth C  |e verfasserin  |4 aut 
700 1 |a Sridhar, Jayanth S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ophthalmic surgery, lasers & imaging retina  |d 2013  |g 53(2022), 11 vom: 15. Nov., Seite 606-609  |w (DE-627)NLM224956647  |x 2325-8179  |7 nnns 
773 1 8 |g volume:53  |g year:2022  |g number:11  |g day:15  |g month:11  |g pages:606-609 
856 4 0 |u http://dx.doi.org/10.3928/23258160-20221019-01  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_40 
912 |a GBV_ILN_63 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_90 
912 |a GBV_ILN_91 
912 |a GBV_ILN_130 
912 |a GBV_ILN_135 
912 |a GBV_ILN_136 
912 |a GBV_ILN_151 
912 |a GBV_ILN_181 
912 |a GBV_ILN_203 
912 |a GBV_ILN_217 
912 |a GBV_ILN_235 
912 |a GBV_ILN_289 
912 |a GBV_ILN_294 
912 |a GBV_ILN_297 
912 |a GBV_ILN_350 
912 |a GBV_ILN_352 
912 |a GBV_ILN_674 
912 |a GBV_ILN_676 
912 |a GBV_ILN_688 
912 |a GBV_ILN_698 
912 |a GBV_ILN_721 
912 |a GBV_ILN_737 
912 |a GBV_ILN_791 
912 |a GBV_ILN_812 
951 |a AR 
952 |d 53  |j 2022  |e 11  |b 15  |c 11  |h 606-609