|
|
|
|
LEADER |
01000caa a22002652c 4500 |
001 |
NLM347845290 |
003 |
DE-627 |
005 |
20250304000956.0 |
007 |
cr uuu---uuuuu |
008 |
231226s2022 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1109/TUFFC.2022.3215436
|2 doi
|
028 |
5 |
2 |
|a pubmed25n1159.xml
|
035 |
|
|
|a (DE-627)NLM347845290
|
035 |
|
|
|a (NLM)36269912
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Wang, Shuo
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Sonodynamic Therapy With Concentric Ultrasound Imaging Array for Precision Theranostics for Atherosclerotic Plaque
|
264 |
|
1 |
|c 2022
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 28.11.2022
|
500 |
|
|
|a Date Revised 16.12.2022
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a Atherosclerotic cardiovascular disease is a major cause of human disability and mortality. Our previous study demonstrated the safety and efficacy of sonodynamic therapy (SDT) on atherosclerotic plaques. However, traditional single-element therapeutic transducer has single acoustic field, and positioning therapeutic and imaging transducers in the same position is difficult during ultrasound imaging-guided SDT. Continuously changing the position of transducers to intervene lesions in different positions is required, increasing the difficulty of treatment. Thus, an SDT device with precise theranostics is required. Therefore, we designed and fabricated a "concentric ultrasound transducer for theranostics" (CUST-T), comprising a central 8-MHz linear array transducer for ultrasound imaging, and a peripheral 1-MHz hollow two-dimensional (2-D) planar array transducer for generating phased-array focused ultrasound (PAFUS). The CUST-T exhibited high imaging resolution at a distance of up to 20 mm from the transducer and could generate a personalized complex PAFUS acoustic field to match various lesions. In vitro biomedical results showed that PAFUS-SDT induced RAW264.7-derived foam cell apoptosis leading to a targeting field apoptotic rate 4.36-6.24 times that of the nontargeting field and the significant apoptotic region was consistent with the PAFUS acoustic field. In vivo, PAFUS-SDT guided by ultrasound imaging significantly increased the lumen area ( ) and collagen level ( ), whereas the wall thickness ( ) and lipid content ( ) of rabbit femoral artery were reduced. In conclusion, CUST-T provided image guidance sufficient for accurate SDT for atherosclerotic plaques in peripheral arteries and could be applied in clinical practice
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
700 |
1 |
|
|a Gao, Zeping
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Yang, Ye
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Zhang, Qi
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Huang, Jiqing
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Wang, Bing
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Lei, Shuang
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tan, Qingyuan
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Liu, Dingyuan
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Guo, Lunhuang
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Song, Yuting
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Liu, Jiamei
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Ma, Teng
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tian, Ye
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t IEEE transactions on ultrasonics, ferroelectrics, and frequency control
|d 1986
|g 69(2022), 12 vom: 10. Dez., Seite 3270-3283
|w (DE-627)NLM098181017
|x 1525-8955
|7 nnas
|
773 |
1 |
8 |
|g volume:69
|g year:2022
|g number:12
|g day:10
|g month:12
|g pages:3270-3283
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1109/TUFFC.2022.3215436
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_24
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 69
|j 2022
|e 12
|b 10
|c 12
|h 3270-3283
|