Metal-Organic Framework UiO-66-Mediated Dual-Signal Ratiometric Electrochemical Sensor for microRNA Detection with DNA Walker Amplification

Electrochemical nanotags with strong signal input are necessary for a ratiometric electrochemical sensor to overcome the drawbacks of inaccurate detection results. In this paper, the metal-organic framework (MOF) UiO-66 was utilized as an electrochemical signal tag. A stable and strong current respo...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 38(2022), 39 vom: 04. Okt., Seite 11828-11836
1. Verfasser: Xie, Fa-Ting (VerfasserIn)
Weitere Verfasser: Li, Yu-Long, Yang, Tong, Yang, Yun-Hui, Hu, Rong
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Electrolytes Metal-Organic Frameworks MicroRNAs Phthalic Acids UiO-66 Biotin 6SO6U10H04 DNA mehr... 9007-49-2 Streptavidin 9013-20-1
LEADER 01000naa a22002652 4500
001 NLM346648793
003 DE-627
005 20231226031945.0
007 cr uuu---uuuuu
008 231226s2022 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.2c00932  |2 doi 
028 5 2 |a pubmed24n1155.xml 
035 |a (DE-627)NLM346648793 
035 |a (NLM)36148509 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Xie, Fa-Ting  |e verfasserin  |4 aut 
245 1 0 |a Metal-Organic Framework UiO-66-Mediated Dual-Signal Ratiometric Electrochemical Sensor for microRNA Detection with DNA Walker Amplification 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 05.10.2022 
500 |a Date Revised 13.10.2022 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Electrochemical nanotags with strong signal input are necessary for a ratiometric electrochemical sensor to overcome the drawbacks of inaccurate detection results. In this paper, the metal-organic framework (MOF) UiO-66 was utilized as an electrochemical signal tag. A stable and strong current response at +0.9 V can be detected in neutral conditions. MicroRNA (miRNA) was employed as the model analyte. Herein, an enzyme-free DNA-walker-based ultrasensitive ratiometric electrochemical biosensor in combination with Zr MOF (UiO-66) signal tags to detect miRNA was demonstrated. In the presence of miRNA, the autonomous walker movement can be initiated by miRNA, leading to the release of biotin-modified fragments. Thus, streptavidin-labeled UiO-66 nanomaterials were not bound to the electrode, generating a low signal response of UiO-66 at +0.9 V. However, the current signal of electrolyte solution as reference at +0.2 V was increased due to the enhancement of electrode conductivity. This ratiometic sensor demonstrated high sensitivity, selectivity, and reproducibility. It can eliminate the disturbance of environmental factors and basic electrode characteristics, providing more accurate signals. A limit of detection (LOD) of 0.17 fM was achieved. Moreover, the method was also used to detect miRNA-21 spiked in real serum samples 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Electrolytes  |2 NLM 
650 7 |a Metal-Organic Frameworks  |2 NLM 
650 7 |a MicroRNAs  |2 NLM 
650 7 |a Phthalic Acids  |2 NLM 
650 7 |a UiO-66  |2 NLM 
650 7 |a Biotin  |2 NLM 
650 7 |a 6SO6U10H04  |2 NLM 
650 7 |a DNA  |2 NLM 
650 7 |a 9007-49-2  |2 NLM 
650 7 |a Streptavidin  |2 NLM 
650 7 |a 9013-20-1  |2 NLM 
700 1 |a Li, Yu-Long  |e verfasserin  |4 aut 
700 1 |a Yang, Tong  |e verfasserin  |4 aut 
700 1 |a Yang, Yun-Hui  |e verfasserin  |4 aut 
700 1 |a Hu, Rong  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 38(2022), 39 vom: 04. Okt., Seite 11828-11836  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:38  |g year:2022  |g number:39  |g day:04  |g month:10  |g pages:11828-11836 
856 4 0 |u http://dx.doi.org/10.1021/acs.langmuir.2c00932  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 38  |j 2022  |e 39  |b 04  |c 10  |h 11828-11836