Management of Internal Ureteral Stent (Double J-Stent) Occlusion

Occlusion of internal ureteral stents commonly called double-J (DJ) stent leads to renal dysfunction, urinary tract infection, and difficulty in replacing the stent. We investigated the cause of stent occlusion and whether DJ stent occlusion persisted with change in the type of stent. The internal u...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Hinyokika kiyo. Acta urologica Japonica. - 1962. - 68(2022), 7 vom: 04. Juli, Seite 233-237
1. Verfasser: Matsumura, Yoshiaki (VerfasserIn)
Weitere Verfasser: Ohmori, Chihiro, Tatsumi, Yoshihiro, Itami, Yoshitaka, Inoue, Takeshi, Samma, Shoji, Kagebayashi, Yoriaki
Format: Online-Aufsatz
Sprache:Japanese
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Hinyokika kiyo. Acta urologica Japonica
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM344442659
003 DE-627
005 20231226022802.0
007 cr uuu---uuuuu
008 231226s2022 xx |||||o 00| ||jpn c
024 7 |a 10.14989/ActaUrolJap_68_7_233  |2 doi 
028 5 2 |a pubmed24n1148.xml 
035 |a (DE-627)NLM344442659 
035 |a (NLM)35924706 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a jpn 
100 1 |a Matsumura, Yoshiaki  |e verfasserin  |4 aut 
245 1 0 |a Management of Internal Ureteral Stent (Double J-Stent) Occlusion 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 05.08.2022 
500 |a Date Revised 05.08.2022 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Occlusion of internal ureteral stents commonly called double-J (DJ) stent leads to renal dysfunction, urinary tract infection, and difficulty in replacing the stent. We investigated the cause of stent occlusion and whether DJ stent occlusion persisted with change in the type of stent. The internal ureteral stent, Bird® Inlay™ Optima or Boston Scientific® Tria™, was inserted in 43 ureters of 33 patients who underwent replacement more than three times between September 2017 and June 2020. We defined stent occlusion as follows: a guide wire could not be passed through a stent during the replacement. In the first occlusion, the type of stent was changed. In the second occlusion, the stent placement interval was shortened from 12-13 weeks to 6-8 weeks. The presence of urinary stone and insertion of a urethral catheter had a high risk of DJ stent occlusion. Stent occlusion was observed in 20 of the 43 ureters. After the type of stent in 20 ureters with stent occlusion was changed, there were no DJ stent occlusions in 16 of the 20 ureters. Nevertheless, in 4 of the 20 ureters, even if we changed the type, DJ stent occlusion was still present; hence, the replacement interval was shortened. Therefore, changing the type of stent may be a recommended intervention for DJ stent occlusion 
650 4 |a Journal Article 
700 1 |a Ohmori, Chihiro  |e verfasserin  |4 aut 
700 1 |a Tatsumi, Yoshihiro  |e verfasserin  |4 aut 
700 1 |a Itami, Yoshitaka  |e verfasserin  |4 aut 
700 1 |a Inoue, Takeshi  |e verfasserin  |4 aut 
700 1 |a Samma, Shoji  |e verfasserin  |4 aut 
700 1 |a Kagebayashi, Yoriaki  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Hinyokika kiyo. Acta urologica Japonica  |d 1962  |g 68(2022), 7 vom: 04. Juli, Seite 233-237  |w (DE-627)NLM012631779  |x 0018-1994  |7 nnns 
773 1 8 |g volume:68  |g year:2022  |g number:7  |g day:04  |g month:07  |g pages:233-237 
856 4 0 |u http://dx.doi.org/10.14989/ActaUrolJap_68_7_233  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_20 
912 |a GBV_ILN_22 
912 |a GBV_ILN_40 
912 |a GBV_ILN_60 
912 |a GBV_ILN_72 
912 |a GBV_ILN_120 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2001 
912 |a GBV_ILN_2003 
912 |a GBV_ILN_2005 
912 |a GBV_ILN_2006 
912 |a GBV_ILN_2008 
912 |a GBV_ILN_2010 
912 |a GBV_ILN_2012 
912 |a GBV_ILN_2018 
951 |a AR 
952 |d 68  |j 2022  |e 7  |b 04  |c 07  |h 233-237