Technical considerations and early results of magnetic compressive intramedullary nailing for humeral shaft delayed unions and nonunions

Background: Expandable magnetic rods and intramedullary nails are being used in a number of innovative ways, including limb length discrepancy and scoliosis correction. However, recently, the full complement of these devices has been further explored, with the utilization of their compressive capaci...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:JSES international. - 2020. - 6(2022), 3 vom: 10. Mai, Seite 385-390
1. Verfasser: Cognetti, Daniel J (VerfasserIn)
Weitere Verfasser: Ghali, Abdullah, Gutierrez-Naranjo, Jose M, Handcox, Jordan, Karia, Ravi, Dutta, Anil K
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:JSES international
Schlagworte:Journal Article Compression Humeral shaft IMN Nail Nonunion PRECICE UNYTE
LEADER 01000caa a22002652c 4500
001 NLM340953152
003 DE-627
005 20250303085414.0
007 cr uuu---uuuuu
008 231226s2022 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jseint.2021.11.022  |2 doi 
028 5 2 |a pubmed25n1136.xml 
035 |a (DE-627)NLM340953152 
035 |a (NLM)35572440 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cognetti, Daniel J  |e verfasserin  |4 aut 
245 1 0 |a Technical considerations and early results of magnetic compressive intramedullary nailing for humeral shaft delayed unions and nonunions 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 16.07.2022 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Background: Expandable magnetic rods and intramedullary nails are being used in a number of innovative ways, including limb length discrepancy and scoliosis correction. However, recently, the full complement of these devices has been further explored, with the utilization of their compressive capacity to improve fracture healing. The purpose of the present study was to report on early results of compressive magnetic intramedullary nailing for humeral shaft delayed unions and nonunions 
520 |a Methods: This retrospective case series was completed at a level 1 trauma center, with adult patients who underwent compressive intramedullary nailing from 2017 to 2021 for humeral shaft nonunion or delayed union. The primary indication for this procedure was nonunion in the setting of previous conventional fixation, but a subset of patients with atrophic nonunions and risk factors for recalcitrant nonunion were also included 
520 |a Results: Fourteen patients, with a mean age of 51 ± 17 years, underwent compressive magnetic intramedullary nailing. Nine patients had previously underwent surgery, 6 of which had undergone multiple prior procedures. Five others were initially treated nonoperatively and underwent surgery 4.1 ± 2.9 months out from injury. Ten patients went on to union at a mean of 2.9 ± 2.4 months. One patient experienced hardware failure with nail cut-out at 2 weeks, and one required revision surgery for a wound infection. Three other patients were lost to follow-up, one of which was deceased for reasons unrelated to surgery 
520 |a Conclusion: Compressive magnetic intramedullary nails are a viable solution for complex humeral shaft nonunions, particularly in the setting of previously well-fixed fractures and those at risk of recalcitrant nonunion. However, comparative and prospective studies looking at union rates and secondary procedures are needed to more clearly define their role in treatment and assure their safety, given recent concerns regarding osteolysis at the nail modular junction 
650 4 |a Journal Article 
650 4 |a Compression 
650 4 |a Humeral shaft 
650 4 |a IMN 
650 4 |a Nail 
650 4 |a Nonunion 
650 4 |a PRECICE 
650 4 |a UNYTE 
700 1 |a Ghali, Abdullah  |e verfasserin  |4 aut 
700 1 |a Gutierrez-Naranjo, Jose M  |e verfasserin  |4 aut 
700 1 |a Handcox, Jordan  |e verfasserin  |4 aut 
700 1 |a Karia, Ravi  |e verfasserin  |4 aut 
700 1 |a Dutta, Anil K  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t JSES international  |d 2020  |g 6(2022), 3 vom: 10. Mai, Seite 385-390  |w (DE-627)NLM307818438  |x 2666-6383  |7 nnas 
773 1 8 |g volume:6  |g year:2022  |g number:3  |g day:10  |g month:05  |g pages:385-390 
856 4 0 |u http://dx.doi.org/10.1016/j.jseint.2021.11.022  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_50 
912 |a GBV_ILN_65 
912 |a GBV_ILN_350 
951 |a AR 