A wide-field micro-computed tomography detector : micron resolution at half-centimetre scale

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 29(2022), Pt 2 vom: 01. März, Seite 505-514
1. Verfasser: Yakovlev, Maksim A (VerfasserIn)
Weitere Verfasser: Vanselow, Daniel J, Ngu, Mee Siing, Zaino, Carolyn R, Katz, Spencer R, Ding, Yifu, Parkinson, Dula, Wang, Steve Yuxin, Ang, Khai Chung, La Riviere, Patrick, Cheng, Keith C
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray optics high resolution histotomography large field of view synchrotron micro-CT
LEADER 01000caa a22002652 4500
001 NLM337853665
003 DE-627
005 20240824232258.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.1107/S160057752101287X  |2 doi 
028 5 2 |a pubmed24n1511.xml 
035 |a (DE-627)NLM337853665 
035 |a (NLM)35254315 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yakovlev, Maksim A  |e verfasserin  |4 aut 
245 1 2 |a A wide-field micro-computed tomography detector  |b micron resolution at half-centimetre scale 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.03.2022 
500 |a Date Revised 24.08.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a open access. 
520 |a Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering 
650 4 |a Journal Article 
650 4 |a X-ray optics 
650 4 |a high resolution 
650 4 |a histotomography 
650 4 |a large field of view 
650 4 |a synchrotron micro-CT 
700 1 |a Vanselow, Daniel J  |e verfasserin  |4 aut 
700 1 |a Ngu, Mee Siing  |e verfasserin  |4 aut 
700 1 |a Zaino, Carolyn R  |e verfasserin  |4 aut 
700 1 |a Katz, Spencer R  |e verfasserin  |4 aut 
700 1 |a Ding, Yifu  |e verfasserin  |4 aut 
700 1 |a Parkinson, Dula  |e verfasserin  |4 aut 
700 1 |a Wang, Steve Yuxin  |e verfasserin  |4 aut 
700 1 |a Ang, Khai Chung  |e verfasserin  |4 aut 
700 1 |a La Riviere, Patrick  |e verfasserin  |4 aut 
700 1 |a Cheng, Keith C  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 29(2022), Pt 2 vom: 01. März, Seite 505-514  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:29  |g year:2022  |g number:Pt 2  |g day:01  |g month:03  |g pages:505-514 