High-speed free-run ptychography at the Australian Synchrotron

open access.

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 29(2022), Pt 2 vom: 01. März, Seite 480-487
Auteur principal: Jones, Michael W M (Auteur)
Autres auteurs: van Riessen, Grant A, Phillips, Nicholas W, Schrank, Christoph E, Hinsley, Gerard N, Afshar, Nader, Reinhardt, Juliane, de Jonge, Martin D, Kewish, Cameron M
Format: Article en ligne
Langue:English
Publié: 2022
Accès à la collection:Journal of synchrotron radiation
Sujets:Journal Article coherent diffractive imaging phase-contrast imaging ptychography scanning X-ray diffraction microscopy ultramicroscopy
LEADER 01000caa a22002652c 4500
001 NLM337853630
003 DE-627
005 20250303031518.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577521012856  |2 doi 
028 5 2 |a pubmed25n1125.xml 
035 |a (DE-627)NLM337853630 
035 |a (NLM)35254312 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Jones, Michael W M  |e verfasserin  |4 aut 
245 1 0 |a High-speed free-run ptychography at the Australian Synchrotron 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.03.2022 
500 |a Date Revised 30.03.2022 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a open access. 
520 |a Over the last decade ptychography has progressed rapidly from a specialist ultramicroscopy technique into a mature method accessible to non-expert users. However, to improve scientific value ptychography data must reconstruct reliably, with high image quality and at no cost to other correlative methods. Presented here is the implementation of high-speed ptychography used at the Australian Synchrotron on the XFM beamline, which includes a free-run data collection mode where dead time is eliminated and the scan time is optimized. It is shown that free-run data collection is viable for fast and high-quality ptychography by demonstrating extremely high data rate acquisition covering areas up to 352 000 µm2 at up to 140 µm2 s-1, with 13× spatial resolution enhancement compared with the beam size. With these improvements, ptychography at velocities up to 250 µm s-1 is approaching speeds compatible with fast-scanning X-ray fluorescence microscopy. The combination of these methods provides morphological context for elemental and chemical information, enabling unique scientific outcomes 
650 4 |a Journal Article 
650 4 |a coherent diffractive imaging 
650 4 |a phase-contrast imaging 
650 4 |a ptychography 
650 4 |a scanning X-ray diffraction microscopy 
650 4 |a ultramicroscopy 
700 1 |a van Riessen, Grant A  |e verfasserin  |4 aut 
700 1 |a Phillips, Nicholas W  |e verfasserin  |4 aut 
700 1 |a Schrank, Christoph E  |e verfasserin  |4 aut 
700 1 |a Hinsley, Gerard N  |e verfasserin  |4 aut 
700 1 |a Afshar, Nader  |e verfasserin  |4 aut 
700 1 |a Reinhardt, Juliane  |e verfasserin  |4 aut 
700 1 |a de Jonge, Martin D  |e verfasserin  |4 aut 
700 1 |a Kewish, Cameron M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 29(2022), Pt 2 vom: 01. März, Seite 480-487  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:29  |g year:2022  |g number:Pt 2  |g day:01  |g month:03  |g pages:480-487 
856 4 0 |u http://dx.doi.org/10.1107/S1600577521012856  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 29  |j 2022  |e Pt 2  |b 01  |c 03  |h 480-487