Synchrotron radiation transmission by two coupled flat microchannel plates : new opportunities to control the focal spot characteristics

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 29(2022), Pt 2 vom: 01. März, Seite 355-362
1. Verfasser: Mazuritskiy, M I (VerfasserIn)
Weitere Verfasser: Lerer, A M, Marcelli, A, Dabagov, S B
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray diffraction X-ray focusing X-ray optics X-ray waveguides microchannel plate
LEADER 01000caa a22002652 4500
001 NLM337853487
003 DE-627
005 20240824232257.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577521012893  |2 doi 
028 5 2 |a pubmed24n1511.xml 
035 |a (DE-627)NLM337853487 
035 |a (NLM)35254297 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Mazuritskiy, M I  |e verfasserin  |4 aut 
245 1 0 |a Synchrotron radiation transmission by two coupled flat microchannel plates  |b new opportunities to control the focal spot characteristics 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 24.08.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a An improved theoretical model to calculate the focal spot properties of coherent synchrotron radiation (SR) soft X-ray beams by combining and aligning two microchannel plates (MCPs) is presented. The diffraction patterns of the radiation behind the MCP system are simulated in the framework of the electrodynamical model of the radiation emission from two-dimensional finite antenna arrays. Simulations show that this particular optical device focuses the soft X-ray radiation in a circular central spot with a radius of ∼4 µm. The study points out that such MCP-based devices may achieve micrometre and sub-micrometre spot sizes as required by many applications in the soft X-ray range. Finally, based on experimental and theoretical results of the radiation transmission by this MCP-based device, a new method to characterize the spatial properties of brilliant SR sources is discussed 
650 4 |a Journal Article 
650 4 |a X-ray diffraction 
650 4 |a X-ray focusing 
650 4 |a X-ray optics 
650 4 |a X-ray waveguides 
650 4 |a microchannel plate 
700 1 |a Lerer, A M  |e verfasserin  |4 aut 
700 1 |a Marcelli, A  |e verfasserin  |4 aut 
700 1 |a Dabagov, S B  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 29(2022), Pt 2 vom: 01. März, Seite 355-362  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:29  |g year:2022  |g number:Pt 2  |g day:01  |g month:03  |g pages:355-362 
856 4 0 |u http://dx.doi.org/10.1107/S1600577521012893  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 29  |j 2022  |e Pt 2  |b 01  |c 03  |h 355-362