|a Response of the VCMVet viscoelastic coagulation monitor to veterinary environmental simulation challenges
|
264 |
|
1 |
|c 2022
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 28.03.2022
|
500 |
|
|
|a Date Revised 01.04.2022
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a © 2022 American Society for Veterinary Clinical Pathology.
|
520 |
|
|
|a BACKGROUND: Traditional viscoelastic clotting tests are significantly impacted by the operator and environmental variation. The VCMVet coagulation monitor could provide a more user-friendly alternative for veterinary practices
|
520 |
|
|
|a OBJECTIVES: We aimed to determine if environmental vibration commonly encountered in veterinary practice alters the results of a point-of-care viscoelastic device, the VCMVet
|
520 |
|
|
|a METHODS: Nine fresh whole blood samples from healthy dogs were evaluated simultaneously using VCMVet instruments under four environmental conditions: (normal) alone and undisturbed on a raised tabletop, (centrifuge) on a countertop 6 inches from a centrifuge that operated at 12 000 rpm for 10 minutes every 20 minutes, (workspace) on a tabletop workspace in proximity to two heavy-use computers, and (gurney) on a rolling gurney at a walking pace for 10 minutes every 20 minutes. Results were compared between conditions using a Friedman test, and if this was significant (P-value < .05), it was followed by a Wilcoxon test for paired samples
|
520 |
|
|
|a RESULTS: Analysis of samples on a rolling gurney created obvious movement artifacts, and this condition was excluded from statistical analysis. The centrifuge condition resulted in a significantly higher alpha angle (median 49 degrees, interquartile range 4) than the normal condition (median 46 degrees, interquartile range 5, P = .0078). Other viscoelastic parameters were not significantly different between the normal, centrifuge, and workspace conditions
|
520 |
|
|
|a CONCLUSIONS: The VCMVet is suitable for use in a busy veterinary environment but should be protected from vibration. The instrument does not produce reliable results when operated on a moving gurney, and it should be stationary during sample analysis
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a canine
|
650 |
|
4 |
|a clinical pathology
|
650 |
|
4 |
|a clotting
|
650 |
|
4 |
|a critical care
|
650 |
|
4 |
|a viscoelastic coagulation
|
700 |
1 |
|
|a Rutter, Christine R
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Pugnetti, Viktoria D
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Jeffery, Unity
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Veterinary clinical pathology
|d 1975
|g 51(2022), 1 vom: 30. März, Seite 45-50
|w (DE-627)NLM098159984
|x 1939-165X
|7 nnns
|
773 |
1 |
8 |
|g volume:51
|g year:2022
|g number:1
|g day:30
|g month:03
|g pages:45-50
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1111/vcp.13041
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 51
|j 2022
|e 1
|b 30
|c 03
|h 45-50
|