Impact of the Inverted Internal Limiting Membrane Flap Diameter on Large Idiopathic Macular Hole Closure : Comparative Randomized Study

BACKGROUND AND OBJECTIVE: To study the impact of the size of internal limiting membrane inverted flap on the rate and timing of large idiopathic macular hole (MH) closure

Bibliographische Detailangaben
Veröffentlicht in:Ophthalmic surgery, lasers & imaging retina. - 2013. - 53(2022), 2 vom: 11. Feb., Seite 103-107
1. Verfasser: Elwan, Mohamed M (VerfasserIn)
Weitere Verfasser: Hagras, Sherein M
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Ophthalmic surgery, lasers & imaging retina
Schlagworte:Journal Article Randomized Controlled Trial
LEADER 01000naa a22002652 4500
001 NLM336803850
003 DE-627
005 20231225232955.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.3928/23258160-20220124-02  |2 doi 
028 5 2 |a pubmed24n1122.xml 
035 |a (DE-627)NLM336803850 
035 |a (NLM)35148213 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Elwan, Mohamed M  |e verfasserin  |4 aut 
245 1 0 |a Impact of the Inverted Internal Limiting Membrane Flap Diameter on Large Idiopathic Macular Hole Closure  |b Comparative Randomized Study 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 08.04.2022 
500 |a Date Revised 08.04.2022 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a BACKGROUND AND OBJECTIVE: To study the impact of the size of internal limiting membrane inverted flap on the rate and timing of large idiopathic macular hole (MH) closure 
520 |a PATIENTS AND METHODS: A prospective randomized comparative study included patients with large idiopathic MH. Eligible eyes underwent pars plana vitrectomy with either inverted small flap (SF < 2 disc diameters) or inverted large flap (LF from 2 to 4 disc diameters). The primary outcome measure included the rate of MH closure at the sixth month. Secondary outcome measures included the timing of MH closure and best-corrected visual acuity 
520 |a RESULTS: Twenty-five eyes were included: 13 in the SF group and 12 in the LF group. At 6 months, the rate of closure was 84.6% in the SF group and 91.6% in the LF group, with no significant difference. Timing of closure was significantly shorter with LF, with better postoperative best-corrected visual acuity 
520 |a CONCLUSION: LF offered a shorter duration for closure with better visual outcomes in large idiopathic MH. [Ophthalmic Surg Lasers Imaging Retina. 2022;53:103-107.] 
650 4 |a Journal Article 
650 4 |a Randomized Controlled Trial 
700 1 |a Hagras, Sherein M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ophthalmic surgery, lasers & imaging retina  |d 2013  |g 53(2022), 2 vom: 11. Feb., Seite 103-107  |w (DE-627)NLM224956647  |x 2325-8179  |7 nnns 
773 1 8 |g volume:53  |g year:2022  |g number:2  |g day:11  |g month:02  |g pages:103-107 
856 4 0 |u http://dx.doi.org/10.3928/23258160-20220124-02  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_40 
912 |a GBV_ILN_63 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_90 
912 |a GBV_ILN_91 
912 |a GBV_ILN_130 
912 |a GBV_ILN_135 
912 |a GBV_ILN_136 
912 |a GBV_ILN_151 
912 |a GBV_ILN_181 
912 |a GBV_ILN_203 
912 |a GBV_ILN_217 
912 |a GBV_ILN_235 
912 |a GBV_ILN_289 
912 |a GBV_ILN_294 
912 |a GBV_ILN_297 
912 |a GBV_ILN_350 
912 |a GBV_ILN_352 
912 |a GBV_ILN_674 
912 |a GBV_ILN_676 
912 |a GBV_ILN_688 
912 |a GBV_ILN_698 
912 |a GBV_ILN_721 
912 |a GBV_ILN_737 
912 |a GBV_ILN_791 
912 |a GBV_ILN_812 
951 |a AR 
952 |d 53  |j 2022  |e 2  |b 11  |c 02  |h 103-107