Assessment of thrombin generation in horses using a calibrated automated thrombogram

© 2022 American Society for Veterinary Clinical Pathology.

Bibliographische Detailangaben
Veröffentlicht in:Veterinary clinical pathology. - 1975. - 51(2022), 1 vom: 07. März, Seite 57-64
1. Verfasser: Leclere, Mathilde (VerfasserIn)
Weitere Verfasser: Chevalier, Zoé, Dubuc, Valérie, Beauchamp, Guy, Bédard, Christian
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Veterinary clinical pathology
Schlagworte:Journal Article coagulopathy hemostatic disorder heparin Anticoagulants Heparin, Low-Molecular-Weight Heparin 9005-49-6 Thrombin EC 3.4.21.5
Beschreibung
Zusammenfassung:© 2022 American Society for Veterinary Clinical Pathology.
BACKGROUND: The amount of thrombin generated reflects the endogenous thrombin potential (ETP), which depends on the balance of pro- and anticoagulant factors. The calibrated automated thrombogram (CAT) allows for the direct measurement of thrombin generation during the clotting process
OBJECTIVES: (1) To describe the results of the CAT assay in horses, (2) to establish intra-assay and intra- and interindividual variation of thrombin generation in healthy horses, and (3) to compare in vitro low-molecular-weight heparin (LMWH) sensitivity between healthy and sick horses. The hypothesis for the last objective is that inhibition of thrombin generation in sick horses requires higher heparin concentrations
METHODS: The plasma of 10 healthy mixed breed horses was used for the determination of normal thrombin generation parameters (lag time, time to peak, peak thrombin concentration, and ETP). Five of the healthy horses were compared with five horses with systemic inflammatory response syndrome (SIRS). In vitro heparin sensitivity was determined using LMWH
RESULTS: The intra-assay variation was small (<5%) for all parameters. Relatively large intra- and interindividual variation were observed in healthy horses. Four of the five sick horses with SIRS had a thrombogram compatible with a hypercoagulable state. The in vitro heparin sensitivity test suggested decreased sensitivity to LMWH in hypercoagulable states
CONCLUSIONS: The CAT assay could detect coagulopathy in horses. In vivo experiments are needed to confirm that it can be used to monitor responses to LMWH therapy
Beschreibung:Date Completed 28.03.2022
Date Revised 01.04.2022
published: Print-Electronic
Citation Status MEDLINE
ISSN:1939-165X
DOI:10.1111/vcp.13055