Oxidation of Congo red by Fenton coupled with micro and nanobubbles

Dye wastewater is a kind of refractory organic wastewater. Fenton coupled with micro-nano bubbles (MNBs+FT) was used for the degradation of Congo red (CR), aiming at simplifying the organic pollutants degradation process and reducing the cost of the process. The optimum condition of Fenton alone, th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1993. - 44(2023), 17 vom: 29. Juli, Seite 2539-2548
1. Verfasser: Ma, Ping (VerfasserIn)
Weitere Verfasser: Han, Chao, He, Qiongqiong, Miao, Zhenyong, Gao, Mingqiang, Wan, Keji, Xu, Enle
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Journal Article Fenton azo dye hydroxyl radical micro-nano bubbles synergy coefficient Congo Red 3U05FHG59S Hydrogen Peroxide BBX060AN9V mehr... Iron E1UOL152H7 methyl-4-nitrobenzenesulfonate 6214-20-6 Wastewater Water Pollutants, Chemical
Beschreibung
Zusammenfassung:Dye wastewater is a kind of refractory organic wastewater. Fenton coupled with micro-nano bubbles (MNBs+FT) was used for the degradation of Congo red (CR), aiming at simplifying the organic pollutants degradation process and reducing the cost of the process. The optimum condition of Fenton alone, the outlet pressure of the cavitation process and different combinations on the degradation of CR dye wastewater were discussed in this study. The results showed that the degradation of CR (100 mg/L) could reach 94.4% by using the MNBs+FT at the pH of 7, which was 72% higher than that using Fenton oxidation alone and 79% higher than that using MNBs alone. Based on the same degradation efficiency, the traditional Fenton process alone required 8 times the dose of oxidants of these combination systems, and the synergy coefficient of MNBs+FT was up to 2.44. ESR analysis indicated that ·OH was the predominant active species during the degradation of CR and MNBs+FT improved the utilization efficiency of H2O2 and produced more ·OH. Besides, the MNBs+FT could extend the pH range of the high-efficiency oxidation reaction, and it could also keep a high degradation rate under neutral conditions, which eliminated the process of adjusting the pH and reduced the anti-corrosion requirements of the equipment. According to the economic analysis results, the total cost of treatment for the MNBs/FT was about 13% of the cost of only the Fenton process. This study provides a reference for the application of MNBs+FT systems in full-scale dye wastewater treatment