The CirPAD, a circular 1.4 M hybrid pixel detector dedicated to X-ray diffraction measurements at Synchrotron SOLEIL

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 29(2022), Pt 1 vom: 01. Jan., Seite 180-193
1. Verfasser: Desjardins, Kewin (VerfasserIn)
Weitere Verfasser: Mocuta, Cristian, Dawiec, Arkadiusz, Réguer, Solenn, Joly, Philippe, Dubuisson, Jean Michel, Alves, Filipe, Noureddine, Arafat, Bompard, Frédéric, Thiaudière, Dominique
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article 2D X-ray diffraction imaging CirPAD DiffAbs X-ray powder diffraction XPAD hybrid pixel X-ray detector
LEADER 01000caa a22002652 4500
001 NLM335208339
003 DE-627
005 20240405232406.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577521012492  |2 doi 
028 5 2 |a pubmed24n1366.xml 
035 |a (DE-627)NLM335208339 
035 |a (NLM)34985435 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Desjardins, Kewin  |e verfasserin  |4 aut 
245 1 4 |a The CirPAD, a circular 1.4 M hybrid pixel detector dedicated to X-ray diffraction measurements at Synchrotron SOLEIL 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 05.04.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a One of the challenges of all synchrotron facilities is to offer the highest performance detectors for all their specific experiments, in particular for X-ray diffraction imaging and its high throughput data collection. In that context, the DiffAbs beamline, the Detectors and the Design and Engineering groups at Synchrotron SOLEIL, in collaboration with ImXPAD and Cegitek companies, have developed an original and unique detector with a circular shape. This detector is based on the hybrid pixel photon-counting technology and consists of the specific assembly of 20 hybrid pixel array detector (XPAD) modules. This article aims to demonstrate the main characteristics of the CirPAD (for Circular Pixel Array Detector) and its performance - i.e. excellent pixel quality, flat-field correction, high-count-rate performance, etc. Additionally, the powder X-ray diffraction pattern of an LaB6 reference sample is presented and refined. The obtained results demonstrate the high quality of the data recorded from the CirPAD, which allows the proposal of its use to all scientific communities interested in performing experiments at the DiffAbs beamline 
650 4 |a Journal Article 
650 4 |a 2D X-ray diffraction imaging 
650 4 |a CirPAD 
650 4 |a DiffAbs 
650 4 |a X-ray powder diffraction 
650 4 |a XPAD 
650 4 |a hybrid pixel X-ray detector 
700 1 |a Mocuta, Cristian  |e verfasserin  |4 aut 
700 1 |a Dawiec, Arkadiusz  |e verfasserin  |4 aut 
700 1 |a Réguer, Solenn  |e verfasserin  |4 aut 
700 1 |a Joly, Philippe  |e verfasserin  |4 aut 
700 1 |a Dubuisson, Jean Michel  |e verfasserin  |4 aut 
700 1 |a Alves, Filipe  |e verfasserin  |4 aut 
700 1 |a Noureddine, Arafat  |e verfasserin  |4 aut 
700 1 |a Bompard, Frédéric  |e verfasserin  |4 aut 
700 1 |a Thiaudière, Dominique  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 29(2022), Pt 1 vom: 01. Jan., Seite 180-193  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:29  |g year:2022  |g number:Pt 1  |g day:01  |g month:01  |g pages:180-193 
856 4 0 |u http://dx.doi.org/10.1107/S1600577521012492  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 29  |j 2022  |e Pt 1  |b 01  |c 01  |h 180-193