An Analysis of Sonothrombolysis and Cavitation for Retracted and Unretracted Clots Using Microbubbles Versus Low-Boiling-Point Nanodroplets

The thrombolysis potential of low-boiling-point (-2 °C) perfluorocarbon phase-change nanodroplets (NDs) has previously been demonstrated on aged clots, and we hypothesized that this efficacy would extend to retracted clots. We tested this hypothesis by comparing sonothrombolysis of both unretracted...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 69(2022), 2 vom: 16. Feb., Seite 711-719
1. Verfasser: Kim, Jinwook (VerfasserIn)
Weitere Verfasser: Bautista, Kathlyne Jayne B, Deruiter, Ryan M, Goel, Leela, Jiang, Xiaoning, Xu, Zhen, Dayton, Paul A
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural
LEADER 01000caa a22002652 4500
001 NLM334684811
003 DE-627
005 20240923232442.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2021.3137125  |2 doi 
028 5 2 |a pubmed24n1545.xml 
035 |a (DE-627)NLM334684811 
035 |a (NLM)34932475 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kim, Jinwook  |e verfasserin  |4 aut 
245 1 3 |a An Analysis of Sonothrombolysis and Cavitation for Retracted and Unretracted Clots Using Microbubbles Versus Low-Boiling-Point Nanodroplets 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 28.03.2022 
500 |a Date Revised 23.09.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The thrombolysis potential of low-boiling-point (-2 °C) perfluorocarbon phase-change nanodroplets (NDs) has previously been demonstrated on aged clots, and we hypothesized that this efficacy would extend to retracted clots. We tested this hypothesis by comparing sonothrombolysis of both unretracted and retracted clots using ND-mediated ultrasound (US+ND) and microbubble-mediated ultrasound (US+MB), respectively. Assessment data included clot mass reduction, cavitation detection, and cavitation cloud imaging in vitro. Acoustic parameters included a 7.9-MPa peak negative pressure and 180-cycle bursts with 5-Hz repetition (the corresponding duty cycle and time-averaged intensity of 0.09% and 1.87 W/cm2, respectively) based on prior studies. With these parameters, we observed a significantly reduced efficacy of US+MB in the retracted versus unretracted model (the averaged mass reduction rate from 1.83%/min to 0.54%/min). Unlike US+MB, US+ND exhibited less reduction of efficacy in the retracted model (from 2.15%/min to 1.04%/min on average). The cavitation detection results correlate with the sonothrombolysis efficacy results showing that both stable and inertial cavitation generated in a retracted clot by US+ND is higher than that by US+MB. We observed that ND-mediated cavitation shows a tendency to occur inside a clot, whereas MB-mediated cavitation occurs near the surface of a retracted clot, and this difference is more significant with retracted clots compared to unretracted clots. We conclude that ND-mediated sonothrombolysis outperforms MB-mediated therapy regardless of clot retraction, and this advantage of ND-mediated cavitation is emphasized for retracted clots. The primary mechanisms are hypothesized to be sustained cavitation level and cavitation clouds in the proximity of a retracted clot by US+ND 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
700 1 |a Bautista, Kathlyne Jayne B  |e verfasserin  |4 aut 
700 1 |a Deruiter, Ryan M  |e verfasserin  |4 aut 
700 1 |a Goel, Leela  |e verfasserin  |4 aut 
700 1 |a Jiang, Xiaoning  |e verfasserin  |4 aut 
700 1 |a Xu, Zhen  |e verfasserin  |4 aut 
700 1 |a Dayton, Paul A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 69(2022), 2 vom: 16. Feb., Seite 711-719  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:69  |g year:2022  |g number:2  |g day:16  |g month:02  |g pages:711-719 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2021.3137125  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 69  |j 2022  |e 2  |b 16  |c 02  |h 711-719