Extension and improvement of the methanol-d4 NMR thermometer calibration

© 2021 The Authors. Magnetic Resonance in Chemistry published by John Wiley & Sons Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 60(2022), 2 vom: 30. Feb., Seite 203-209
1. Verfasser: Karschin, Niels (VerfasserIn)
Weitere Verfasser: Krenek, Stephan, Heyer, Dieter, Griesinger, Christian
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2022
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article Research Support, Non-U.S. Gov't 1H NMR NMR thermometer calibration methanol Methanol Y4S76JWI15
LEADER 01000naa a22002652 4500
001 NLM33028603X
003 DE-627
005 20231225210944.0
007 cr uuu---uuuuu
008 231225s2022 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.5216  |2 doi 
028 5 2 |a pubmed24n1100.xml 
035 |a (DE-627)NLM33028603X 
035 |a (NLM)34486171 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Karschin, Niels  |e verfasserin  |4 aut 
245 1 0 |a Extension and improvement of the methanol-d4 NMR thermometer calibration 
264 1 |c 2022 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 04.03.2022 
500 |a Date Revised 04.03.2022 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2021 The Authors. Magnetic Resonance in Chemistry published by John Wiley & Sons Ltd. 
520 |a NMR thermometers are a convenient way to determine the temperature inside the sample of an NMR spectrometer. They rely on signals with strongly temperature-dependent chemical shifts, often of OH groups; 99.8% perdeuterated methanol is an established example which is particularly well suited for modern, high-sensitivity spectrometers, but it is so far calibrated only in the range of 282 to 330 K. In this work, we extend this calibration to the entire liquid range of methanol, 175 to 338 K. Additionally, we use a temperature sensor calibrated traceably to the International Temperature Scale (ITS-90) and accounted for the magnetic field effect on the sensor, yielding a more accurate calibration curve with an uncertainty (2σ) varying between 25 and 190 mK 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a 1H 
650 4 |a NMR 
650 4 |a NMR thermometer 
650 4 |a calibration 
650 4 |a methanol 
650 7 |a Methanol  |2 NLM 
650 7 |a Y4S76JWI15  |2 NLM 
700 1 |a Krenek, Stephan  |e verfasserin  |4 aut 
700 1 |a Heyer, Dieter  |e verfasserin  |4 aut 
700 1 |a Griesinger, Christian  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 60(2022), 2 vom: 30. Feb., Seite 203-209  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:60  |g year:2022  |g number:2  |g day:30  |g month:02  |g pages:203-209 
856 4 0 |u http://dx.doi.org/10.1002/mrc.5216  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 60  |j 2022  |e 2  |b 30  |c 02  |h 203-209