Energy efficiency assessment of China wastewater treatment plants by unit energy consumption per kg COD removed

Unit energy consumption per kg pollutant removed (kWh/kgCODremoved) is used for the first time in assessing and ranking the sustainability of main treatment technologies of 1215 wastewater treatment plants (WWTPs) in China. The metric better measures the sustainability of main treatment technologies...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1993. - 44(2023), 2 vom: 16. Jan., Seite 278-292
1. Verfasser: Li, Jinze (VerfasserIn)
Weitere Verfasser: Tang, Walter Z, Gu, Li
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Journal Article Anaerobic-oxic plus anaerobic–anoxic–oxic Energy benchmarking Oxidation ditch Sequencing batch reactor Unit energy consumption