Assessment of oil-interceptor performance for solid removal in highway runoff

Oil interceptors are traditional SuDS devices used in highway runoff treatment to remove both floatable impurities (leaves, oil) and total suspended solids (TSS). This paper presents the results of an examination of the performance of an oil interceptor based on particle size distribution (PSD) and...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1993. - 44(2023), 2 vom: 09. Jan., Seite 197-210
1. Verfasser: Zakharova, Julia (VerfasserIn)
Weitere Verfasser: Pouran, Hamid, Wheatley, Andrew, Arif, Mohammed
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2023
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Journal Article ADWP SuDS highway runoff oil interceptor particle size distribution milbemycin oxime 0502PUN0GT
LEADER 01000caa a22002652c 4500
001 NLM329242768
003 DE-627
005 20250302084050.0
007 cr uuu---uuuuu
008 231225s2023 xx |||||o 00| ||eng c
024 7 |a 10.1080/09593330.2021.1968040  |2 doi 
028 5 2 |a pubmed25n1097.xml 
035 |a (DE-627)NLM329242768 
035 |a (NLM)34380379 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zakharova, Julia  |e verfasserin  |4 aut 
245 1 0 |a Assessment of oil-interceptor performance for solid removal in highway runoff 
264 1 |c 2023 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.01.2023 
500 |a Date Revised 18.01.2023 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Oil interceptors are traditional SuDS devices used in highway runoff treatment to remove both floatable impurities (leaves, oil) and total suspended solids (TSS). This paper presents the results of an examination of the performance of an oil interceptor based on particle size distribution (PSD) and TSS during three rainfall events. The interceptor is situated on one of the busiest motorways in the UK (where peak traffic flow is 30,000 vehicles per hour). Although the overall data collected for this study provided evidence that the interceptor removed, in most cases, 70% of TSS, the data for particle size distribution (PSD) showed that the interceptor did not always cope with particle separation for particles of less than 25 μm diameter 
650 4 |a Journal Article 
650 4 |a ADWP 
650 4 |a SuDS 
650 4 |a highway runoff 
650 4 |a oil interceptor 
650 4 |a particle size distribution 
650 7 |a milbemycin oxime  |2 NLM 
650 7 |a 0502PUN0GT  |2 NLM 
700 1 |a Pouran, Hamid  |e verfasserin  |4 aut 
700 1 |a Wheatley, Andrew  |e verfasserin  |4 aut 
700 1 |a Arif, Mohammed  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Environmental technology  |d 1993  |g 44(2023), 2 vom: 09. Jan., Seite 197-210  |w (DE-627)NLM098202545  |x 1479-487X  |7 nnas 
773 1 8 |g volume:44  |g year:2023  |g number:2  |g day:09  |g month:01  |g pages:197-210 
856 4 0 |u http://dx.doi.org/10.1080/09593330.2021.1968040  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 44  |j 2023  |e 2  |b 09  |c 01  |h 197-210