Reducing the thermal deformation of InSb crystal by using double-bounce HHRMs in the TPS tender X-ray absorption spectroscopy beamline
The Taiwan Photon Source (TPS) with high brightness and energy tunability is suitable for applications in spectroscopy. The tender X-ray absorption beamline will be optimized for X-ray absorption spectroscopy measurements using a bending-magnet source in a unique photon energy range (1.7-10 keV) and...
Ausführliche Beschreibung
Bibliographische Detailangaben
Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 28(2021), Pt 4 vom: 01. Juli, Seite 1202-1209
|
1. Verfasser: |
Liu, Din Goa
(VerfasserIn) |
Weitere Verfasser: |
Lee, Ming Han,
Lu, Ying Jui,
Lee, Jyh Fu,
Chen, Chi Liang |
Format: | Online-Aufsatz
|
Sprache: | English |
Veröffentlicht: |
2021
|
Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation
|
Schlagworte: | Journal Article
InSb crystal
double-bounce HHRMs
tender XAS