Computational fluid dynamics modelling of quasi-collimated beam apparatus - a typical bench scale UV apparatus for water treatment

Quasi-collimated beam apparatus (QCBA), a typical bench scale UV apparatus, is crucial for the biodosimetry determination of UV dose in target reactors. However, the key parameters for the QCBA construction are usually estimated via rule-of-thumb calculations. Computational fluid dynamics models are...

Description complète

Détails bibliographiques
Publié dans:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 83(2021), 10 vom: 25. Mai, Seite 2526-2535
Auteur principal: Lian, Junfeng (Auteur)
Autres auteurs: Sun, Liangmin, Jiang, Chong, Li, Wentao, Zhu, Yichun, Qin, Xinxin, Liu, Zuwen
Format: Article en ligne
Langue:English
Publié: 2021
Accès à la collection:Water science and technology : a journal of the International Association on Water Pollution Research
Sujets:Journal Article
LEADER 01000caa a22002652c 4500
001 NLM325817995
003 DE-627
005 20250301175318.0
007 cr uuu---uuuuu
008 231225s2021 xx |||||o 00| ||eng c
024 7 |a 10.2166/wst.2021.144  |2 doi 
028 5 2 |a pubmed25n1085.xml 
035 |a (DE-627)NLM325817995 
035 |a (NLM)34032628 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Lian, Junfeng  |e verfasserin  |4 aut 
245 1 0 |a Computational fluid dynamics modelling of quasi-collimated beam apparatus - a typical bench scale UV apparatus for water treatment 
264 1 |c 2021 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 27.05.2021 
500 |a Date Revised 27.05.2021 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Quasi-collimated beam apparatus (QCBA), a typical bench scale UV apparatus, is crucial for the biodosimetry determination of UV dose in target reactors. However, the key parameters for the QCBA construction are usually estimated via rule-of-thumb calculations. Computational fluid dynamics models are applied in this study to simulate the UV fluence rate (FR) distributions in QCBAs. QCBAs with either a cylindrical tube or successive apertures irradiate quasi parallel light into selected dishes. The simulated Petri factors (PF) in the target QCBAs with a single aperture were all >0.84, and increased with the extended distance (L1) from the UV lamp to the upper aperture. QCBAs with two successive apertures are recommended compared with those with three apertures or cylindrical tube. A trend of FR distribution from dispersed to concentrated is observed when L1 or the interval distance between each aperture increases in a dual-aperture QCBA. QCBAs with multiple lamps were favorable to increase the UV output power, while having a nearly negligible loss of parallelism. An actual QCBA was constructed, and the maximal and average FR and PF values in a 60-mm dish were 0.159 and 0.164 W/m2, and 0.967, respectively, in accordance with the simulated results 
650 4 |a Journal Article 
700 1 |a Sun, Liangmin  |e verfasserin  |4 aut 
700 1 |a Jiang, Chong  |e verfasserin  |4 aut 
700 1 |a Li, Wentao  |e verfasserin  |4 aut 
700 1 |a Zhu, Yichun  |e verfasserin  |4 aut 
700 1 |a Qin, Xinxin  |e verfasserin  |4 aut 
700 1 |a Liu, Zuwen  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 83(2021), 10 vom: 25. Mai, Seite 2526-2535  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnas 
773 1 8 |g volume:83  |g year:2021  |g number:10  |g day:25  |g month:05  |g pages:2526-2535 
856 4 0 |u http://dx.doi.org/10.2166/wst.2021.144  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 83  |j 2021  |e 10  |b 25  |c 05  |h 2526-2535