Time-Resolved Passive Cavitation Mapping Using the Transient Angular Spectrum Approach

Passive cavitation mapping (PCM), which generates images using bubble acoustic emission signals, has been increasingly used for monitoring and guiding focused ultrasound surgery (FUS). PCM can be used as an adjunct to magnetic resonance imaging to provide crucial information on the safety and effica...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 68(2021), 7 vom: 03. Juli, Seite 2361-2369
1. Verfasser: Li, Mucong (VerfasserIn)
Weitere Verfasser: Gu, Juanjuan, Vu, Tri, Sankin, Georgy, Zhong, Pei, Yao, Junjie, Jing, Yun
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2021
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM321939271
003 DE-627
005 20240812231859.0
007 cr uuu---uuuuu
008 231225s2021 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2021.3062357  |2 doi 
028 5 2 |a pubmed24n1499.xml 
035 |a (DE-627)NLM321939271 
035 |a (NLM)33635787 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Mucong  |e verfasserin  |4 aut 
245 1 0 |a Time-Resolved Passive Cavitation Mapping Using the Transient Angular Spectrum Approach 
264 1 |c 2021 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 25.10.2021 
500 |a Date Revised 12.08.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Passive cavitation mapping (PCM), which generates images using bubble acoustic emission signals, has been increasingly used for monitoring and guiding focused ultrasound surgery (FUS). PCM can be used as an adjunct to magnetic resonance imaging to provide crucial information on the safety and efficacy of FUS. The most widely used algorithm for PCM is delay-and-sum (DAS). One of the major limitations of DAS is its suboptimal computational efficiency. Although frequency-domain DAS can partially resolve this issue, such an algorithm is not suitable for imaging the evolution of bubble activity in real time and for cases in which cavitation events occur asynchronously. This study investigates a transient angular spectrum (AS) approach for PCM. The working principle of this approach is to backpropagate the received signal to the domain of interest and reconstruct the spatial-temporal wavefield encoded with the bubble location and collapse time. The transient AS approach is validated using an in silico model and water bath experiments. It is found that the transient AS approach yields similar results to DAS, but it is one order of magnitude faster. The results obtained by this study suggest that the transient AS approach is promising for fast and accurate PCM 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Gu, Juanjuan  |e verfasserin  |4 aut 
700 1 |a Vu, Tri  |e verfasserin  |4 aut 
700 1 |a Sankin, Georgy  |e verfasserin  |4 aut 
700 1 |a Zhong, Pei  |e verfasserin  |4 aut 
700 1 |a Yao, Junjie  |e verfasserin  |4 aut 
700 1 |a Jing, Yun  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 68(2021), 7 vom: 03. Juli, Seite 2361-2369  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:68  |g year:2021  |g number:7  |g day:03  |g month:07  |g pages:2361-2369 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2021.3062357  |3 Volltext 