A high-rate and stable nitrogen removal from reject water in a full-scale two-stage AMX® system

This paper reports long-term performance of a two-stage AMX® system with a capacity of 70 m3/d treating actual reject water. An air-lift granulation reactor performed partial nitritation (PN-AGR) at an average nitrogen loading rate (NLR) of 3.1 kgN/m3-d, producing an average effluent NO2--N/NH4+-N r...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 83(2021), 3 vom: 25. Feb., Seite 652-663
1. Verfasser: Jung, Minki (VerfasserIn)
Weitere Verfasser: Oh, Taeseok, Rhu, Daehwan, Liberzon, Jon, Kang, S Joh, Daigger, Glen T, Kim, Sungpyo
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2021
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Ammonium Compounds Waste Water Water 059QF0KO0R Nitrogen N762921K75