Counting-loss correction method based on dual-exponential impulse shaping
Under the condition of high counting rate, the phenomenon of nuclear pulse signal pile-up using a single exponential impulse shaping method is still very serious, and leads to a severe loss in counting rate. A real nuclear pulse signal can be expressed as a dual-exponential decay function with a cer...
Ausführliche Beschreibung
Bibliographische Detailangaben
Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 27(2020), Pt 6 vom: 01. Nov., Seite 1609-1613
|
1. Verfasser: |
Liu, Yi
(VerfasserIn) |
Weitere Verfasser: |
Wang, Ming,
Wan, Wenjie,
Zhou, Jianbin,
Hong, Xu,
Liu, Fei,
Yu, Jie |
Format: | Online-Aufsatz
|
Sprache: | English |
Veröffentlicht: |
2020
|
Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation
|
Schlagworte: | Journal Article
counting loss correction
dead-time
dual-exponential signal
unit-impulse-response |