Clinical Evaluation of Individualized and Navigated Microsecond Pulsing Laser for Acute Central Serous Chorioretinopathy

Copyright 2020, SLACK Incorporated.

Bibliographische Detailangaben
Veröffentlicht in:Ophthalmic surgery, lasers & imaging retina. - 2013. - 51(2020), 9 vom: 01. Sept., Seite 512-520
1. Verfasser: Volodin, Pavel L (VerfasserIn)
Weitere Verfasser: Ivanova, Elena V
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Ophthalmic surgery, lasers & imaging retina
Schlagworte:Journal Article
LEADER 01000caa a22002652c 4500
001 NLM315269057
003 DE-627
005 20250228012213.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.3928/23258160-20200831-06  |2 doi 
028 5 2 |a pubmed25n1050.xml 
035 |a (DE-627)NLM315269057 
035 |a (NLM)32955591 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Volodin, Pavel L  |e verfasserin  |4 aut 
245 1 0 |a Clinical Evaluation of Individualized and Navigated Microsecond Pulsing Laser for Acute Central Serous Chorioretinopathy 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 28.07.2021 
500 |a Date Revised 28.07.2021 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Copyright 2020, SLACK Incorporated. 
520 |a BACKGROUND AND OBJECTIVE: A computational model has predicted parameters for using a navigated microsecond pulsing laser system to treat central serous chorioretinopathy (CSC) 
520 |a PATIENTS AND METHODS: A prospective, single-center, interventional case series was conducted for patients with acute CSC who were enrolled following screening and informed consent. Treatment involved laser pulse duration of 50 μs, 2.4% Duty Cycle, 100 μm spot size, and 10 ms pulse duration 
520 |a RESULTS: Average best-corrected visual acuity (decimal) of 12 patients improved from 0.86 ± 0.03 at baseline to 0.97 ± 0.01 at 3 months. Baseline central retinal thickness decreased from 452.58 μm ± 24.53 μm at baseline to 249.25 μm ± 2.92 μm at 3 months. Retinal sensitivity improved from 24.1 dB ± 1.09 dB at baseline to 28.98 dB ± 0.23 dB at 3 months. In all cases, subretinal fluid was resorbed 
520 |a CONCLUSION: The parameter sets derived from the computer model can be applied safely and effectively for CSC treatment using the navigated microsecond pulsing laser system. [Ophthalmic Surg Lasers Imaging Retina. 2020;51:512-520.] 
650 4 |a Journal Article 
700 1 |a Ivanova, Elena V  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ophthalmic surgery, lasers & imaging retina  |d 2013  |g 51(2020), 9 vom: 01. Sept., Seite 512-520  |w (DE-627)NLM224956647  |x 2325-8179  |7 nnas 
773 1 8 |g volume:51  |g year:2020  |g number:9  |g day:01  |g month:09  |g pages:512-520 
856 4 0 |u http://dx.doi.org/10.3928/23258160-20200831-06  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_40 
912 |a GBV_ILN_63 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_90 
912 |a GBV_ILN_91 
912 |a GBV_ILN_130 
912 |a GBV_ILN_135 
912 |a GBV_ILN_136 
912 |a GBV_ILN_151 
912 |a GBV_ILN_181 
912 |a GBV_ILN_203 
912 |a GBV_ILN_217 
912 |a GBV_ILN_235 
912 |a GBV_ILN_289 
912 |a GBV_ILN_294 
912 |a GBV_ILN_297 
912 |a GBV_ILN_350 
912 |a GBV_ILN_352 
912 |a GBV_ILN_674 
912 |a GBV_ILN_676 
912 |a GBV_ILN_688 
912 |a GBV_ILN_698 
912 |a GBV_ILN_721 
912 |a GBV_ILN_737 
912 |a GBV_ILN_791 
912 |a GBV_ILN_812 
951 |a AR 
952 |d 51  |j 2020  |e 9  |b 01  |c 09  |h 512-520