Open-Channel Capillary Trees and Capillary Pumping

Velocity of capillary flow in closed or open channels decreases as the flow proceeds down the length of the channel, varying as the inverse of the square root of time or as the inverse of travel distance. In order to increase the flow rate-and extend the duration of the flow-capillary pumps have bee...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1999. - 36(2020), 43 vom: 03. Nov., Seite 12795-12803
1. Verfasser: Lee, Jing J (VerfasserIn)
Weitere Verfasser: Berthier, Jean, Kearney, Kathleen E, Berthier, Erwin, Theberge, Ashleigh B
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM315084928
003 DE-627
005 20240402232337.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.0c01360  |2 doi 
028 5 2 |a pubmed24n1360.xml 
035 |a (DE-627)NLM315084928 
035 |a (NLM)32936651 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Lee, Jing J  |e verfasserin  |4 aut 
245 1 0 |a Open-Channel Capillary Trees and Capillary Pumping 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 21.06.2021 
500 |a Date Revised 02.04.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Velocity of capillary flow in closed or open channels decreases as the flow proceeds down the length of the channel, varying as the inverse of the square root of time or as the inverse of travel distance. In order to increase the flow rate-and extend the duration of the flow-capillary pumps have been designed by mimicking the pumping principle of paper or cotton fibers. These designs provide a larger volume available for the wicking of the liquids. In microsystems for biotechnology, different designs have been developed based on experimental observation. In the present paper, the mechanisms at the basis of capillary pumping are investigated using a theoretical model for the flow in an open-channel "capillary tree" (i.e., an ensemble of channels with bifurcations mimicking the shape of a tree). The model is checked against experiments. Rules for obtaining better designs of capillary pumps are proposed; specifically, we find (1) when using a capillary tree with identical channel cross-sectional areas throughout, it is possible to maintain nearly constant flow rates throughout the channel network, (2) flow rate can be increased at each branch point of a capillary tree by slightly decreasing the areas of the channel cross section and decreasing the channel lengths at each level of ramification within the tree, and (3) higher order branching (trifurcations vs bifurcations) amplify the flow rate effect. This work lays the foundation for increasing the flow rate in open microfluidic channels driven by capillary flow; we expect this to have broad impact across open microfluidics for biological and chemical applications such as cell culture, sample preparation, separations, and on-chip reactions 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Berthier, Jean  |e verfasserin  |4 aut 
700 1 |a Kearney, Kathleen E  |e verfasserin  |4 aut 
700 1 |a Berthier, Erwin  |e verfasserin  |4 aut 
700 1 |a Theberge, Ashleigh B  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1999  |g 36(2020), 43 vom: 03. Nov., Seite 12795-12803  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:36  |g year:2020  |g number:43  |g day:03  |g month:11  |g pages:12795-12803 
856 4 0 |u http://dx.doi.org/10.1021/acs.langmuir.0c01360  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 36  |j 2020  |e 43  |b 03  |c 11  |h 12795-12803