Pushing the temporal resolution in absorption and Zernike phase contrast nanotomography : enabling fast in situ experiments

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 27(2020), Pt 5 vom: 01. Sept., Seite 1339-1346
1. Verfasser: Flenner, Silja (VerfasserIn)
Weitere Verfasser: Storm, Malte, Kubec, Adam, Longo, Elena, Döring, Florian, Pelt, Daniël M, David, Christian, Müller, Martin, Greving, Imke
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Zernike phase contrast full-field X-ray microscopy image quality in situ experiments nanotomography time resolution
LEADER 01000naa a22002652 4500
001 NLM314495584
003 DE-627
005 20231225152845.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577520007407  |2 doi 
028 5 2 |a pubmed24n1048.xml 
035 |a (DE-627)NLM314495584 
035 |a (NLM)32876609 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Flenner, Silja  |e verfasserin  |4 aut 
245 1 0 |a Pushing the temporal resolution in absorption and Zernike phase contrast nanotomography  |b enabling fast in situ experiments 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 12.11.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a Hard X-ray nanotomography enables 3D investigations of a wide range of samples with high resolution (<100 nm) with both synchrotron-based and laboratory-based setups. However, the advantage of synchrotron-based setups is the high flux, enabling time resolution, which cannot be achieved at laboratory sources. Here, the nanotomography setup at the imaging beamline P05 at PETRA III is presented, which offers high time resolution not only in absorption but for the first time also in Zernike phase contrast. Two test samples are used to evaluate the image quality in both contrast modalities based on the quantitative analysis of contrast-to-noise ratio (CNR) and spatial resolution. High-quality scans can be recorded in 15 min and fast scans down to 3 min are also possible without significant loss of image quality. At scan times well below 3 min, the CNR values decrease significantly and classical image-filtering techniques reach their limitation. A machine-learning approach shows promising results, enabling acquisition of a full tomography in only 6 s. Overall, the transmission X-ray microscopy instrument offers high temporal resolution in absorption and Zernike phase contrast, enabling in situ experiments at the beamline 
650 4 |a Journal Article 
650 4 |a Zernike phase contrast 
650 4 |a full-field X-ray microscopy 
650 4 |a image quality 
650 4 |a in situ experiments 
650 4 |a nanotomography 
650 4 |a time resolution 
700 1 |a Storm, Malte  |e verfasserin  |4 aut 
700 1 |a Kubec, Adam  |e verfasserin  |4 aut 
700 1 |a Longo, Elena  |e verfasserin  |4 aut 
700 1 |a Döring, Florian  |e verfasserin  |4 aut 
700 1 |a Pelt, Daniël M  |e verfasserin  |4 aut 
700 1 |a David, Christian  |e verfasserin  |4 aut 
700 1 |a Müller, Martin  |e verfasserin  |4 aut 
700 1 |a Greving, Imke  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 27(2020), Pt 5 vom: 01. Sept., Seite 1339-1346  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:27  |g year:2020  |g number:Pt 5  |g day:01  |g month:09  |g pages:1339-1346 
856 4 0 |u http://dx.doi.org/10.1107/S1600577520007407  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 27  |j 2020  |e Pt 5  |b 01  |c 09  |h 1339-1346