Stable sub-micrometre high-flux probe for soft X-ray ARPES using a monolithic Wolter mirror
open access.
| Publié dans: | Journal of synchrotron radiation. - 1994. - 27(2020), Pt 5 vom: 01. Sept., Seite 1103-1107 |
|---|---|
| Auteur principal: | |
| Autres auteurs: | , , , , , |
| Format: | Article en ligne |
| Langue: | English |
| Publié: |
2020
|
| Accès à la collection: | Journal of synchrotron radiation |
| Sujets: | Journal Article ARPES Wolter mirror focusing optics monolithic soft X-rays |
| Résumé: | open access. A focusing optics that can provide a sub-micrometre high-flux probe for soft X-ray micrometre-scale angle-resolved photoemission spectroscopy (ARPES) is proposed. A monolithic Wolter-type mirror with a large acceptance, achromatism and small comatic aberration was designed and evaluated. A focused beam size of 0.4 µm (vertical) × 4 µm (horizontal), a high throughput of 59% and a high tolerance of 1.6 mrad to the pitching error were realized at a photon energy of 1000 eV. A Wolter-type mirror can be practically employed as a stable sub-micrometre focusing mirror with high throughput in ARPES applications |
|---|---|
| Description: | Date Revised 16.09.2020 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
| ISSN: | 1600-5775 |
| DOI: | 10.1107/S1600577520007274 |