PtyNAMi : ptychographic nano-analytical microscope

© Andreas Schropp et al. 2020.

Bibliographische Detailangaben
Veröffentlicht in:Journal of applied crystallography. - 1998. - 53(2020), Pt 4 vom: 01. Aug., Seite 957-971
1. Verfasser: Schropp, Andreas (VerfasserIn)
Weitere Verfasser: Döhrmann, Ralph, Botta, Stephan, Brückner, Dennis, Kahnt, Maik, Lyubomirskiy, Mikhail, Ossig, Christina, Scholz, Maria, Seyrich, Martin, Stuckelberger, Michael E, Wiljes, Patrik, Wittwer, Felix, Garrevoet, Jan, Falkenberg, Gerald, Fam, Yakub, Sheppard, Thomas L, Grunwaldt, Jan-Dierk, Schroer, Christian G
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of applied crystallography
Schlagworte:Journal Article X-ray imaging in situ imaging multi-modal imaging ptychography tomography
LEADER 01000naa a22002652 4500
001 NLM313636273
003 DE-627
005 20231225151011.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600576720008420  |2 doi 
028 5 2 |a pubmed24n1045.xml 
035 |a (DE-627)NLM313636273 
035 |a (NLM)32788903 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Schropp, Andreas  |e verfasserin  |4 aut 
245 1 0 |a PtyNAMi  |b ptychographic nano-analytical microscope 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 11.11.2023 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © Andreas Schropp et al. 2020. 
520 |a Ptychographic X-ray imaging at the highest spatial resolution requires an optimal experimental environment, providing a high coherent flux, excellent mechanical stability and a low background in the measured data. This requires, for example, a stable performance of all optical components along the entire beam path, high temperature stability, a robust sample and optics tracking system, and a scatter-free environment. This contribution summarizes the efforts along these lines to transform the nanoprobe station on beamline P06 (PETRA III) into the ptychographic nano-analytical microscope (PtyNAMi) 
650 4 |a Journal Article 
650 4 |a X-ray imaging 
650 4 |a in situ imaging 
650 4 |a multi-modal imaging 
650 4 |a ptychography 
650 4 |a tomography 
700 1 |a Döhrmann, Ralph  |e verfasserin  |4 aut 
700 1 |a Botta, Stephan  |e verfasserin  |4 aut 
700 1 |a Brückner, Dennis  |e verfasserin  |4 aut 
700 1 |a Kahnt, Maik  |e verfasserin  |4 aut 
700 1 |a Lyubomirskiy, Mikhail  |e verfasserin  |4 aut 
700 1 |a Ossig, Christina  |e verfasserin  |4 aut 
700 1 |a Scholz, Maria  |e verfasserin  |4 aut 
700 1 |a Seyrich, Martin  |e verfasserin  |4 aut 
700 1 |a Stuckelberger, Michael E  |e verfasserin  |4 aut 
700 1 |a Wiljes, Patrik  |e verfasserin  |4 aut 
700 1 |a Wittwer, Felix  |e verfasserin  |4 aut 
700 1 |a Garrevoet, Jan  |e verfasserin  |4 aut 
700 1 |a Falkenberg, Gerald  |e verfasserin  |4 aut 
700 1 |a Fam, Yakub  |e verfasserin  |4 aut 
700 1 |a Sheppard, Thomas L  |e verfasserin  |4 aut 
700 1 |a Grunwaldt, Jan-Dierk  |e verfasserin  |4 aut 
700 1 |a Schroer, Christian G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of applied crystallography  |d 1998  |g 53(2020), Pt 4 vom: 01. Aug., Seite 957-971  |w (DE-627)NLM098121561  |x 0021-8898  |7 nnns 
773 1 8 |g volume:53  |g year:2020  |g number:Pt 4  |g day:01  |g month:08  |g pages:957-971 
856 4 0 |u http://dx.doi.org/10.1107/S1600576720008420  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2020  |e Pt 4  |b 01  |c 08  |h 957-971