Design Considerations for Frequency Shifts in a Laterally Finite FBAR Sensor in Contact With the Newtonian Liquid

Mode-coupled vibrations in a thickness-shear (TSh) mode and laterally finite film bulk acoustic resonator (FBAR) with one face in contact with Newtonian (linearly viscous and compressional) liquid are investigated. With boundary conditions and interface continuity conditions, exact dispersion curves...

Description complète

Détails bibliographiques
Publié dans:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 67(2020), 11 vom: 21. Nov., Seite 2402-2412
Auteur principal: Zhao, Zinan (Auteur)
Autres auteurs: Wang, Bin, Qian, Zhenghua, Kuznetsova, Iren, Ma, Tingfeng, Yong, Yook-Kong
Format: Article en ligne
Langue:English
Publié: 2020
Accès à la collection:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Sujets:Journal Article
Description
Résumé:Mode-coupled vibrations in a thickness-shear (TSh) mode and laterally finite film bulk acoustic resonator (FBAR) with one face in contact with Newtonian (linearly viscous and compressional) liquid are investigated. With boundary conditions and interface continuity conditions, exact dispersion curves in FBAR sensors contacting with two kinds of liquids are obtained, and they are compared with the dispersion curves in a bare sensor without liquid contact. Frequency spectra, describing mode couplings between the main TSh modal branch and undesirable modal branches, are calculated by employing weak boundary conditions at lateral free edges constructed based on the variational principle. Mode shapes of mechanical displacements in both the sensor and liquid layer are presented, and mode transformations are observed due to the liquid contact and lateral edge effect. The effect of liquid thickness on frequency spectra is also studied. Numerical results reveal that the generation of shear wave in the liquid layer results in the shifts of spectrum curves along the frequency axis and hence it is the main factor of frequency shifts of FBAR sensors. The compressional wave causes the shifts of spectrum curves along the lateral aspect ratio axis. Then for a given FBAR sensor, the liquid thickness changes could also cause frequency shifts. Therefore, desirable vibration modes should be chosen based on the frequency spectra to avoid strong mode couplings and to eliminate frequency shifts induced by the liquid thickness changes in real applications
Description:Date Revised 26.10.2020
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:1525-8955
DOI:10.1109/TUFFC.2020.3006186