Near, far, wherever you are : simulations on the dose efficiency of holographic and ptychographic coherent imaging

© Ming Du et al. 2020.

Bibliographische Detailangaben
Veröffentlicht in:Journal of applied crystallography. - 1998. - 53(2020), Pt 3 vom: 01. Juni, Seite 748-759
1. Verfasser: Du, Ming (VerfasserIn)
Weitere Verfasser: Gürsoy, Doǧa, Jacobsen, Chris
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of applied crystallography
Schlagworte:Journal Article X-ray microscopy holography ptychography radiation dose
LEADER 01000naa a22002652 4500
001 NLM312612141
003 DE-627
005 20231225144806.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600576720005816  |2 doi 
028 5 2 |a pubmed24n1042.xml 
035 |a (DE-627)NLM312612141 
035 |a (NLM)32684890 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Du, Ming  |e verfasserin  |4 aut 
245 1 0 |a Near, far, wherever you are  |b simulations on the dose efficiency of holographic and ptychographic coherent imaging 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 11.11.2023 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © Ming Du et al. 2020. 
520 |a Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution 
650 4 |a Journal Article 
650 4 |a X-ray microscopy 
650 4 |a holography 
650 4 |a ptychography 
650 4 |a radiation dose 
700 1 |a Gürsoy, Doǧa  |e verfasserin  |4 aut 
700 1 |a Jacobsen, Chris  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of applied crystallography  |d 1998  |g 53(2020), Pt 3 vom: 01. Juni, Seite 748-759  |w (DE-627)NLM098121561  |x 0021-8898  |7 nnns 
773 1 8 |g volume:53  |g year:2020  |g number:Pt 3  |g day:01  |g month:06  |g pages:748-759 
856 4 0 |u http://dx.doi.org/10.1107/S1600576720005816  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2020  |e Pt 3  |b 01  |c 06  |h 748-759