Estimation of white blood cell and platelet counts in ovine blood smears, and a comparison with the ADVIA 120 hematology analyzer

© 2020 American Society for Veterinary Clinical Pathology.

Bibliographische Detailangaben
Veröffentlicht in:Veterinary clinical pathology. - 1975. - 49(2020), 2 vom: 04. Juni, Seite 222-226
1. Verfasser: Katsogiannou, Eleni G (VerfasserIn)
Weitere Verfasser: Athanasiou, Labrini V, Katsoulos, Panagiotis D, Polizopoulou, Zoe S, Tzivara, Athanasia, Christodoulopoulos, Georgios
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Veterinary clinical pathology
Schlagworte:Comparative Study Journal Article blood smear hematology analyzer manual platelet count sheep white blood cell count
LEADER 01000caa a22002652c 4500
001 NLM311182550
003 DE-627
005 20250227103649.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1111/vcp.12871  |2 doi 
028 5 2 |a pubmed25n1037.xml 
035 |a (DE-627)NLM311182550 
035 |a (NLM)32539178 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Katsogiannou, Eleni G  |e verfasserin  |4 aut 
245 1 0 |a Estimation of white blood cell and platelet counts in ovine blood smears, and a comparison with the ADVIA 120 hematology analyzer 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 29.03.2021 
500 |a Date Revised 29.03.2021 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2020 American Society for Veterinary Clinical Pathology. 
520 |a BACKGROUND: Manual evaluation of blood cell counts on stained blood films is a common procedure in resource-limited laboratories of farm animal clinics. Moreover, settings for sheep blood cell counts are not provided on most veterinary hematology analyzers 
520 |a OBJECTIVES: We aimed to (a) compare the results of white blood cell (WBC) counts evaluated microscopically on ovine blood smears with those obtained by the ADVIA 120 hematology analyzer and validate appropriate correction factors for the manual technique; and (b) assess the two suggested factors to calculate platelet counts on blood smears in sheep 
520 |a METHODS: The blood samples of 57 sheep were used to generate a regression equation between the average WBC count per field and the WBC count determined using the ADVIA 120 analyzer. Thirty-one new ovine samples were used to assess the agreement between the calculated WBC counts based on a generated equation and those obtained by the analyzer using the Passing-Bablok test and Bland-Altman plots. Similarly, agreements between platelet counts using two different factors for platelet calculation were assessed using the Bland-Altman plot 
520 |a RESULTS: The average bias of calculated WBC counts was 0.4%, with precision and accuracy being over 95%. Regarding calculated platelet counts, Bland-Altman plots revealed a bias of 26.4% and 1.4% when the average number of platelets per field was multiplied by 15 000 and 20 000, respectively 
520 |a CONCLUSIONS: Microscopic WBC counting in ovine blood is a reliable alternative to automated analyses using the generated equation. A better agreement between the two methods was observed when a factor of 20 000 was used to calculate platelet counts in ovine blood smears 
650 4 |a Comparative Study 
650 4 |a Journal Article 
650 4 |a blood smear 
650 4 |a hematology analyzer 
650 4 |a manual 
650 4 |a platelet count 
650 4 |a sheep 
650 4 |a white blood cell count 
700 1 |a Athanasiou, Labrini V  |e verfasserin  |4 aut 
700 1 |a Katsoulos, Panagiotis D  |e verfasserin  |4 aut 
700 1 |a Polizopoulou, Zoe S  |e verfasserin  |4 aut 
700 1 |a Tzivara, Athanasia  |e verfasserin  |4 aut 
700 1 |a Christodoulopoulos, Georgios  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Veterinary clinical pathology  |d 1975  |g 49(2020), 2 vom: 04. Juni, Seite 222-226  |w (DE-627)NLM098159984  |x 1939-165X  |7 nnas 
773 1 8 |g volume:49  |g year:2020  |g number:2  |g day:04  |g month:06  |g pages:222-226 
856 4 0 |u http://dx.doi.org/10.1111/vcp.12871  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 49  |j 2020  |e 2  |b 04  |c 06  |h 222-226