Concentrated protein solutions investigated using acoustic levitation and small-angle X-ray scattering

An acoustically levitated droplet has been used to collect synchrotron SAXS data on human serum albumin protein solutions up to a protein concentration of 400 mg ml-1. A careful selection of experiments allows for fast data collection of a large amount of data, spanning a protein concentration/solve...

Description complète

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 27(2020), Pt 2 vom: 01. März, Seite 396-404
Auteur principal: Sønderby, Pernille (Auteur)
Autres auteurs: Söderberg, Christopher, Frankær, Christian G, Peters, Günther, Bukrinski, Jens T, Labrador, Ana, Plivelic, Tomás S, Harris, Pernille
Format: Article en ligne
Langue:English
Publié: 2020
Accès à la collection:Journal of synchrotron radiation
Sujets:Journal Article SAXS concentrated protein solutions levitated droplet structure factors Serum Albumin
LEADER 01000caa a22002652c 4500
001 NLM307415821
003 DE-627
005 20250226220842.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577519016977  |2 doi 
028 5 2 |a pubmed25n1024.xml 
035 |a (DE-627)NLM307415821 
035 |a (NLM)32153278 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sønderby, Pernille  |e verfasserin  |4 aut 
245 1 0 |a Concentrated protein solutions investigated using acoustic levitation and small-angle X-ray scattering 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 29.01.2021 
500 |a Date Revised 29.01.2021 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a An acoustically levitated droplet has been used to collect synchrotron SAXS data on human serum albumin protein solutions up to a protein concentration of 400 mg ml-1. A careful selection of experiments allows for fast data collection of a large amount of data, spanning a protein concentration/solvent concentration space with limited sample consumption (down to 3 µL per experiment) and few measurements. The data analysis shows data of high quality that are reproducible and comparable with data from standard flow-through capillary-based experiments. Furthermore, using this methodology, it is possible to achieve concentrations that would not be accessible by conventional cells. The protein concentration and ionic strength parameter space diagram may be covered easily and the amount of protein sample is significantly reduced (by a factor of 100 in this work). Used in routine measurements, the benefits in terms of protein cost and time spent are very significant 
650 4 |a Journal Article 
650 4 |a SAXS 
650 4 |a concentrated protein solutions 
650 4 |a levitated droplet 
650 4 |a structure factors 
650 7 |a Serum Albumin  |2 NLM 
700 1 |a Söderberg, Christopher  |e verfasserin  |4 aut 
700 1 |a Frankær, Christian G  |e verfasserin  |4 aut 
700 1 |a Peters, Günther  |e verfasserin  |4 aut 
700 1 |a Bukrinski, Jens T  |e verfasserin  |4 aut 
700 1 |a Labrador, Ana  |e verfasserin  |4 aut 
700 1 |a Plivelic, Tomás S  |e verfasserin  |4 aut 
700 1 |a Harris, Pernille  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 27(2020), Pt 2 vom: 01. März, Seite 396-404  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:27  |g year:2020  |g number:Pt 2  |g day:01  |g month:03  |g pages:396-404 
856 4 0 |u http://dx.doi.org/10.1107/S1600577519016977  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 27  |j 2020  |e Pt 2  |b 01  |c 03  |h 396-404