Iterative energy self-calibration of Fe XANES spectra

Determining the oxidation state of Fe through parameterization of X-ray absorption near-edge structure (XANES) spectral features is highly dependent on accurate and repeatable energy calibration between spectra. Small errors in energy calibration can lead to vastly different interpretations. While s...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 27(2020), Pt 1 vom: 01. Jan., Seite 207-211
1. Verfasser: Jones, Michael W M (VerfasserIn)
Weitere Verfasser: Mallmann, Guilherme, Wykes, Jeremy L, Knafelc, Joseph, Bryan, Scott E, Howard, Daryl L
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Fe XANES Havre pumice RGM-2 energy calibration mid-ocean ridge basalt (MORB) rhyolite
LEADER 01000naa a22002652 4500
001 NLM304692069
003 DE-627
005 20231225115528.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577519014267  |2 doi 
028 5 2 |a pubmed24n1015.xml 
035 |a (DE-627)NLM304692069 
035 |a (NLM)31868753 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Jones, Michael W M  |e verfasserin  |4 aut 
245 1 0 |a Iterative energy self-calibration of Fe XANES spectra 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.12.2019 
500 |a Date Revised 11.02.2021 
500 |a published: Print-Electronic 
500 |a ErratumIn: J Synchrotron Radiat. 2020 Jul 1;27(Pt 4):1092-1093. - PMID 33566021 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Determining the oxidation state of Fe through parameterization of X-ray absorption near-edge structure (XANES) spectral features is highly dependent on accurate and repeatable energy calibration between spectra. Small errors in energy calibration can lead to vastly different interpretations. While simultaneous measurement of a reference foil is often undertaken on X-ray spectroscopy beamlines, other beamlines measure XANES spectra without a reference foil and therefore lack a method for correcting energy drift. Here a method is proposed that combines two measures of Fe oxidation state taken from different parts of the spectrum to iteratively correct for an unknown energy offset between spectra, showing successful iterative self-calibration not only during individual beam time but also across different beamlines 
650 4 |a Journal Article 
650 4 |a Fe XANES 
650 4 |a Havre pumice 
650 4 |a RGM-2 
650 4 |a energy calibration 
650 4 |a mid-ocean ridge basalt (MORB) 
650 4 |a rhyolite 
700 1 |a Mallmann, Guilherme  |e verfasserin  |4 aut 
700 1 |a Wykes, Jeremy L  |e verfasserin  |4 aut 
700 1 |a Knafelc, Joseph  |e verfasserin  |4 aut 
700 1 |a Bryan, Scott E  |e verfasserin  |4 aut 
700 1 |a Howard, Daryl L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 27(2020), Pt 1 vom: 01. Jan., Seite 207-211  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:27  |g year:2020  |g number:Pt 1  |g day:01  |g month:01  |g pages:207-211 
856 4 0 |u http://dx.doi.org/10.1107/S1600577519014267  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 27  |j 2020  |e Pt 1  |b 01  |c 01  |h 207-211