Application of coagulation-ultrafiltration-nanofiltration in a pilot study for Tai Lake water treatment

© 2019 Water Environment Federation.

Bibliographische Detailangaben
Veröffentlicht in:Water environment research : a research publication of the Water Environment Federation. - 1998. - 92(2020), 4 vom: 27. Apr., Seite 579-587
1. Verfasser: Li, Tian (VerfasserIn)
Weitere Verfasser: Zhang, Yunlu, Gui, Bo, Gao, Kuo, Zhao, Qingqing, Qu, Ruixin, Liu, Tuodong, Hoffmann, Michael, Staaks, Christian, Dong, Bingzhi
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Water environment research : a research publication of the Water Environment Federation
Schlagworte:Journal Article inline coagulation membrane fouling nanofiltration pilot study ultrafiltration Humic Substances Membranes, Artificial
LEADER 01000naa a22002652 4500
001 NLM301678170
003 DE-627
005 20231225105127.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1002/wer.1247  |2 doi 
028 5 2 |a pubmed24n1005.xml 
035 |a (DE-627)NLM301678170 
035 |a (NLM)31560133 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Tian  |e verfasserin  |4 aut 
245 1 0 |a Application of coagulation-ultrafiltration-nanofiltration in a pilot study for Tai Lake water treatment 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 03.04.2020 
500 |a Date Revised 03.04.2020 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2019 Water Environment Federation. 
520 |a In this study, the inline coagulation was combined with ultrafiltration and nanofiltration (UF-NF) in a pilot study for Tai Lake water treatment. The results showed that the combination process was very effective for Tai Lake water treatment in terms of organic removal and membrane fouling control. With inline coagulation, no irreversible membrane fouling was observed for either UF or NF at fluxes of 65-90 and 22-26 L/(m2  hr), respectively. The membrane foulants were analyzed, and the results indicated that the low molecular weight fractions in the feed were main membrane fouling contributors for both UF and NF, where hydrophilic substances and proteins, as well as neutral substances and humic acids with polycarboxyl groups, contributed significantly to UF and NF membrane fouling, respectively. Compared with direct UF-NF filtration without coagulation, the coagulants could aggregate organic micromolecules for cake formation. With inline coagulation, the moving flocs could generate shear stress to scrub the membrane surface for fouling control of UF. Moreover, with inline coagulation, the organics removal efficiency could be further increased by 10%-20%. With NF, the permeate had a TOC concentration of less than 0.5 mg/L, satisfying the drinking water quality. Therefore, the coagulation-UF-NF is very useful for Tai Lake water treatment. PRACTITIONER POINTS: Inline coagulation-UF-NF for Tai Lake Water treatment is implemented. Inline coagulation can aggregate hydrophilic substances to reduce membrane fouling. Moving flocs produce shear stress for fouling control of UF-NF. Superior quality of permeate is achieved with the combined coagulation-UF-NF process 
650 4 |a Journal Article 
650 4 |a inline coagulation 
650 4 |a membrane fouling 
650 4 |a nanofiltration 
650 4 |a pilot study 
650 4 |a ultrafiltration 
650 7 |a Humic Substances  |2 NLM 
650 7 |a Membranes, Artificial  |2 NLM 
700 1 |a Zhang, Yunlu  |e verfasserin  |4 aut 
700 1 |a Gui, Bo  |e verfasserin  |4 aut 
700 1 |a Gao, Kuo  |e verfasserin  |4 aut 
700 1 |a Zhao, Qingqing  |e verfasserin  |4 aut 
700 1 |a Qu, Ruixin  |e verfasserin  |4 aut 
700 1 |a Liu, Tuodong  |e verfasserin  |4 aut 
700 1 |a Hoffmann, Michael  |e verfasserin  |4 aut 
700 1 |a Staaks, Christian  |e verfasserin  |4 aut 
700 1 |a Dong, Bingzhi  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water environment research : a research publication of the Water Environment Federation  |d 1998  |g 92(2020), 4 vom: 27. Apr., Seite 579-587  |w (DE-627)NLM098214292  |x 1554-7531  |7 nnns 
773 1 8 |g volume:92  |g year:2020  |g number:4  |g day:27  |g month:04  |g pages:579-587 
856 4 0 |u http://dx.doi.org/10.1002/wer.1247  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 92  |j 2020  |e 4  |b 27  |c 04  |h 579-587