Linear array detector for online diagnostics of spectral distributions at MHz repetition rates

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 26(2019), Pt 5 vom: 01. Sept., Seite 1514-1522
1. Verfasser: Gerth, Christopher (VerfasserIn)
Weitere Verfasser: Brenner, Günter, Caselle, Michele, Düsterer, Stefan, Haack, Daniel, Makowski, Dariusz, Mielczarek, Aleksander, Palutke, Steffen, Rota, Lorenzo, Rybnikov, Vladimir, Schmidt, Christian, Steffen, Bernd, Tiedtke, Kai
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article extreme ultraviolet radiation free-electron laser high repetition rate diagnostics line scan camera linear array detector soft X-ray spectroscopy
LEADER 01000caa a22002652 4500
001 NLM300991223
003 DE-627
005 20240719232303.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577519007835  |2 doi 
028 5 2 |a pubmed24n1475.xml 
035 |a (DE-627)NLM300991223 
035 |a (NLM)31490139 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Gerth, Christopher  |e verfasserin  |4 aut 
245 1 0 |a Linear array detector for online diagnostics of spectral distributions at MHz repetition rates 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 25.02.2020 
500 |a Date Revised 19.07.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a open access. 
520 |a Free-electron lasers (FELs) based on superconducting accelerator technology and storage ring facilities operate with bunch repetition rates in the MHz range, and the need arises for bunch-by-bunch electron and photon diagnostics. For photon-pulse-resolved measurements of spectral distributions, fast one-dimensional profile monitors are required. The linear array detector KALYPSO (KArlsruhe Linear arraY detector for MHz-rePetition rate SpectrOscopy) has been developed for electron bunch or photon pulse synchronous read-out with frame rates of up to 2.7 MHz. At the FLASH facility at DESY, a current version of KALYPSO with 256 pixels has been installed at a grating spectrometer as online diagnostics to monitor the pulse-resolved spectra of the high-repetition-rate FEL pulses. Application-specific front-end electronics based on MicroTCA standard have been developed for data acquisition and processing. Continuous data read-out with low latency in the microsecond range enables the integration into fast feedback applications. In this paper, pulse-resolved FEL spectra recorded at 1.0 MHz repetition rate for various operation conditions at FLASH are presented, and the first application of an adaptive feedback for accelerator control based on photon beam diagnostics is demonstrated 
650 4 |a Journal Article 
650 4 |a extreme ultraviolet radiation 
650 4 |a free-electron laser 
650 4 |a high repetition rate diagnostics 
650 4 |a line scan camera 
650 4 |a linear array detector 
650 4 |a soft X-ray spectroscopy 
700 1 |a Brenner, Günter  |e verfasserin  |4 aut 
700 1 |a Caselle, Michele  |e verfasserin  |4 aut 
700 1 |a Düsterer, Stefan  |e verfasserin  |4 aut 
700 1 |a Haack, Daniel  |e verfasserin  |4 aut 
700 1 |a Makowski, Dariusz  |e verfasserin  |4 aut 
700 1 |a Mielczarek, Aleksander  |e verfasserin  |4 aut 
700 1 |a Palutke, Steffen  |e verfasserin  |4 aut 
700 1 |a Rota, Lorenzo  |e verfasserin  |4 aut 
700 1 |a Rybnikov, Vladimir  |e verfasserin  |4 aut 
700 1 |a Schmidt, Christian  |e verfasserin  |4 aut 
700 1 |a Steffen, Bernd  |e verfasserin  |4 aut 
700 1 |a Tiedtke, Kai  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 26(2019), Pt 5 vom: 01. Sept., Seite 1514-1522  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:26  |g year:2019  |g number:Pt 5  |g day:01  |g month:09  |g pages:1514-1522 
856 4 0 |u http://dx.doi.org/10.1107/S1600577519007835  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 26  |j 2019  |e Pt 5  |b 01  |c 09  |h 1514-1522