Fast Hydrophobicity Recovery of the Surface-Hydrophilic Poly(dimethylsiloxane) Films Caused by Rechemisorption of Dimethylsiloxane Derivatives

Long-term stability of the surface hydrophilicity of poly(dimethylsiloxane) (PDMS) remains a critical issue for a wide range of applications including, e.g., biomedical materials, biochip devices, and microfluidics. Although several mechanisms for recovering hydrophobicity have been proposed, none h...

Description complète

Détails bibliographiques
Publié dans:Langmuir : the ACS journal of surfaces and colloids. - 1985. - 35(2019), 30 vom: 30. Juli, Seite 9747-9752
Auteur principal: Senzai, Takahiro (Auteur)
Autres auteurs: Fujikawa, Shigenori
Format: Article en ligne
Langue:English
Publié: 2019
Accès à la collection:Langmuir : the ACS journal of surfaces and colloids
Sujets:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM299001032
003 DE-627
005 20250225143614.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.9b01448  |2 doi 
028 5 2 |a pubmed25n0996.xml 
035 |a (DE-627)NLM299001032 
035 |a (NLM)31286768 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Senzai, Takahiro  |e verfasserin  |4 aut 
245 1 0 |a Fast Hydrophobicity Recovery of the Surface-Hydrophilic Poly(dimethylsiloxane) Films Caused by Rechemisorption of Dimethylsiloxane Derivatives 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 26.06.2020 
500 |a Date Revised 26.06.2020 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Long-term stability of the surface hydrophilicity of poly(dimethylsiloxane) (PDMS) remains a critical issue for a wide range of applications including, e.g., biomedical materials, biochip devices, and microfluidics. Although several mechanisms for recovering hydrophobicity have been proposed, none has been proven unequivocally. We discovered that the hydrophobic recovery of surface-oxidized PDMS films was accelerated when the films were stored in a closed chamber under an atmosphere containing dimethylsiloxane derivatives such as octamethylcyclotetrasiloxane, which had evaporated from the films and were detected by gas chromatography-mass spectrometry measurements. X-ray photoelectron spectroscopy and quartz crystal microbalance measurements were used to monitor the chemical deposition of the derivatives on the surface-oxidized substrates, and the formation of a hydrophobic dimethyl silicone layer rendered the oxidized surfaces hydrophobic again. In the absence of superficial hydrophilic functional groups, volatile species did not react with the surface, and the hydrophobic dimethyl silicone layer did not form. The results show that the formation of a thin layer of dimethylsiloxane derivatives by chemisorption is a new mechanism for recovering the surface hydrophobicity of PDMS films 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Fujikawa, Shigenori  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1985  |g 35(2019), 30 vom: 30. Juli, Seite 9747-9752  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:35  |g year:2019  |g number:30  |g day:30  |g month:07  |g pages:9747-9752 
856 4 0 |u http://dx.doi.org/10.1021/acs.langmuir.9b01448  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 35  |j 2019  |e 30  |b 30  |c 07  |h 9747-9752