Proficiency Testing in a Laboratory Accreditation Program for the Bacterial Ring Rot Pathogen of Potato

Variability of enzyme-linked immunosorbent assay (ELISA) and immunofluorescence tests for the detection of Clavibacter michiganensis subsp. sepedonicus in potato tissue was analyzed to determine the magnitude of repeatability (within analyst variation) and reproducibility (among analyst variation) c...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Plant disease. - 1997. - 84(2000), 6 vom: 30. Juni, Seite 649-653
1. Verfasser: De Boer, S H (VerfasserIn)
Weitere Verfasser: Hall, J W
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2000
Zugriff auf das übergeordnete Werk:Plant disease
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM294651217
003 DE-627
005 20231225081941.0
007 cr uuu---uuuuu
008 231225s2000 xx |||||o 00| ||eng c
024 7 |a 10.1094/PDIS.2000.84.6.649  |2 doi 
028 5 2 |a pubmed24n0982.xml 
035 |a (DE-627)NLM294651217 
035 |a (NLM)30841105 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a De Boer, S H  |e verfasserin  |4 aut 
245 1 0 |a Proficiency Testing in a Laboratory Accreditation Program for the Bacterial Ring Rot Pathogen of Potato 
264 1 |c 2000 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Variability of enzyme-linked immunosorbent assay (ELISA) and immunofluorescence tests for the detection of Clavibacter michiganensis subsp. sepedonicus in potato tissue was analyzed to determine the magnitude of repeatability (within analyst variation) and reproducibility (among analyst variation) components. The analysis was based on data generated by analysts in eight laboratories testing proficiency panel samples distributed under a laboratory accreditation program. The standard deviation for repeatability of the ELISA test was small but increased at higher absorbance readings, while the standard deviation for reproducibility was larger and also increased at high absorbances. For immunofluorescence, the standard deviation for repeatability and reproducibility were similar to one another and increased with increasing bacterial concentration, as might be expected for count data and the inherent subjectivity of the test. The reproducibility standard deviation provided the basis for calculating "z-scores" by the Association of Official Analytical Chemists' procedure to evaluate proficiency of chemical analyses. More than 90 and 80% of the z-scores for samples tested in this study by ELISA and immunofluorescence, respectively, were in the acceptable range. The rescaled sums of z-scores for individual analysts were used as single combination scores to evaluate each analyst's results over all samples of a proficiency panel. This measure may be useful for tracking analyst performance on process control charts as part of a quality control system 
650 4 |a Journal Article 
700 1 |a Hall, J W  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Plant disease  |d 1997  |g 84(2000), 6 vom: 30. Juni, Seite 649-653  |w (DE-627)NLM098181742  |x 0191-2917  |7 nnns 
773 1 8 |g volume:84  |g year:2000  |g number:6  |g day:30  |g month:06  |g pages:649-653 
856 4 0 |u http://dx.doi.org/10.1094/PDIS.2000.84.6.649  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 84  |j 2000  |e 6  |b 30  |c 06  |h 649-653