Cable shared dual-frequency catheter for intravascular ultrasound

This study proposes a catheter consisting of dual-frequency transducer for intravascular ultrasound. Both ultrasonic elements with different frequencies were connected to one coaxial cable to make the connection simple. The aperture size of the ultrasound elements were 0.4×0.6 mm2 and 0.3×0.4 mm2 fo...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - (2019) vom: 11. Feb.
1. Verfasser: Su, Min (VerfasserIn)
Weitere Verfasser: Zhang, Zhiqiang, Hong, Jiehan, Huang, Yaocai, Mu, Peitian, Yu, Yanyan, Liu, Rong, Liang, Suzi, Zheng, Hairong, Qiu, Weibao
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652c 4500
001 NLM293881200
003 DE-627
005 20250224203906.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2019.2898256  |2 doi 
028 5 2 |a pubmed25n0979.xml 
035 |a (DE-627)NLM293881200 
035 |a (NLM)30762542 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Su, Min  |e verfasserin  |4 aut 
245 1 0 |a Cable shared dual-frequency catheter for intravascular ultrasound 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 27.02.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a This study proposes a catheter consisting of dual-frequency transducer for intravascular ultrasound. Both ultrasonic elements with different frequencies were connected to one coaxial cable to make the connection simple. The aperture size of the ultrasound elements were 0.4×0.6 mm2 and 0.3×0.4 mm2 for the low frequency element and high frequency element, respectively. The center frequency and bandwidth of the fabricated low frequency transducer were 33.8 MHz and 49.3%, respectively. Meanwhile, the center frequency and bandwidth of the high frequency transducer were 80.6 MHz and 50.3%, respectively. Imaging evaluations of wire phantom, tissue phantom and vessel tissue demonstrated good imaging capability of the dual-frequency catheter. The spatial resolution are 19 μm axially and 128 μm laterally for the high frequency transducer, and 37 μm axially and 199 μm laterally for the low frequency transducer. Band-pass filters were designed to separate the mixed echo signals. After filtering, the images from different ultrasound elements can be successfully identified, indicating the feasibility of the proposed cable shared dual-frequency imaging strategy. The proposed method has simple structure, good imaging resolution, and large penetration depth, showing good application prospect for intravascular ultrasound 
650 4 |a Journal Article 
700 1 |a Zhang, Zhiqiang  |e verfasserin  |4 aut 
700 1 |a Hong, Jiehan  |e verfasserin  |4 aut 
700 1 |a Huang, Yaocai  |e verfasserin  |4 aut 
700 1 |a Mu, Peitian  |e verfasserin  |4 aut 
700 1 |a Yu, Yanyan  |e verfasserin  |4 aut 
700 1 |a Liu, Rong  |e verfasserin  |4 aut 
700 1 |a Liang, Suzi  |e verfasserin  |4 aut 
700 1 |a Zheng, Hairong  |e verfasserin  |4 aut 
700 1 |a Qiu, Weibao  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g (2019) vom: 11. Feb.  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnas 
773 1 8 |g year:2019  |g day:11  |g month:02 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2019.2898256  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2019  |b 11  |c 02